The effect of medial calcar screws on the treatment of Neer type Ⅲ proximal humeral fracture with Multiloc intramedullary nailing
10.3760/cma.j.cn115530-20230201-00064
- VernacularTitle:内侧距螺钉对Multiloc髓内钉治疗肱骨近端Neer Ⅲ型骨折术后疗效的影响
- Author:
Xingxing ZHANG
1
;
Fei DAI
;
Ming XIANG
Author Information
1. 成都中医药大学,成都 610075
- Keywords:
Shoulder joint;
Fracture fixation, internal;
Bone nails;
Proximal humerus fractures;
Medial calcar screw
- From:
Chinese Journal of Orthopaedic Trauma
2023;25(5):427-432
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the effect of the use of medial calcar screws on the treatment of Neer type Ⅲ proximal humeral fracture with Multiloc intramedullary nailing.Methods:A retrospective study was conducted to analyze the data of 36 patients with Near type Ⅲ fracture of the proximal humerus who had received Multiloc intramedullary nailing at Department of Upper Limbs, Sichuan Orthopedic Hospital from January 2016 to December 2021. There were 6 males and 30 females with an age of (63.9±5.3) years. They were divided into 2 groups according to whether medial calcar screws had been used or not. There were 17 cases in the group without medial calcar screws and 19 cases in the group with medial calcar screws. The 2 groups were compared in terms of flexion and lifting, external rotation, internal rotation and back touch, visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Constant-Murley score for shoulder function (Constant score), neck shaft angle, and incidence of complications at the last follow-up.Results:There were no statistically significant significances in the preoperative general data between the 2 groups, indicating comparability between the groups ( P>0.05). The 36 patients were followed up for 13.5(12.0,19.8) months after surgery. The flexion and lifting, external rotation, internal rotation and back touch, VAS, ASES score, Constant score, neck shaft angle at the last follow-up in the group without medial calcar screws were, respectively, 134.1°±8.4°, 32.1°±5.3°, 14.0 (13.0, 15.5) , 0.0 (0.0, 1.0), 78.2±5.2, 78.0±5.8, and 137.6°±8.1°, insignificantly different from those in the group with medial calcar screws [134.7°±6.1°, 35.0(30.0, 35.0)°, 14.0(13.0, 15.0), 1.0 (0.0, 1.0), 78.2±5.4, 76.7±4.5, and 136.9°±6.4°] ( P>0.05). Postoperative complications occurred in 6 patients in each group, showing no statistically significant difference between the 2 groups ( P=1.000). Conclusion:The use of medial calcar screws has no significant impact on the postoperative shoulder function and incidence of complications in the treatment of Neer type Ⅲ fractures of the proximal humerus with Multiloc intramedullary nailing.