The Relationship with the Density of Lens Nucleus and Phacoemulsification Time.
- Author:
Tae Hyung KOO
1
;
Sung Kun CHUNG
;
Nam Ho BAEK
Author Information
1. Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Publication Type:Original Article
- Keywords:
Density of lens nucleus;
Phacoemulsification time;
Scheimpflug camera
- MeSH:
Cataract;
Humans;
Phacoemulsification*
- From:Journal of the Korean Ophthalmological Society
1998;39(5):912-917
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
To investigate the relationship of the density, thickness of lens nucleus and cortex with phacoemulsification time, we measured the preoperative density and length of lens nucleus and cortex of 100 eyes with a Scheimpflug camera. We performed phacoemulsification on the same phacoemulsification technique using a phacoemulsifier aspirator by the same surgeon. The preoperative mean values of the density of lens nucleus and cortex were 127. 09+/-57.44 and 30. 33+/-15. 24, respectively. The mean values of the thickness for both were 3.05+/-0.42mm and 0.65+/-0.17mm, respectively. The mean value of phacoemulsification time was 92.68+/-56.98 seconds. The phacoemulsification time was increased significantly as the density of lens nucleus was increased (P<0.0001). However, the thickness of the lens nucleus and cortex and the density of cortex had no significant effect on the phacoemulsification time (p=0. 235, p=0.811). Preoperative evaluation with a Scheimpflug camera is particularly valuable for cataractous patients with corneal endothelial disease deciding on phacoemulsification.