Clinical effect of minimally invasive catheterization based on computer 3D-Slicer software system in the treatment of hypertensive intracerebral hemorrhage
10.3760/cma.j.cn115455-20210528-00709
- VernacularTitle:基于计算机3D-Slicer软件系统实施微创穿刺置管术治疗高血压脑出血的临床效果探讨
- Author:
Jiaying YANG
1
;
Lei WANG
;
Zong GAO
Author Information
1. 兰陵县人民医院神经外科,临沂 277700
- Keywords:
Intracranial hemorrhage, hypertensive;
Catheterization;
Minimally invasive surgical procedures;
Treatment outcome;
3D-Slicer software
- From:
Chinese Journal of Postgraduates of Medicine
2023;46(2):167-171
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the clinical effect of minimally invasive catheterization based on computer 3D-Slicer software system in the treatment of hypertensive intracerebral hemorrhage (HICH).Methods:Three hundred and fifty patients with HICH treated in People′s Hospital of Lanling County in Shandongfrom June 2019 to June 2020 were selected as the research object. According to the operation method, they were divided into 3D-Slicer group (175 cases) and CT group (175 cases). They were treated with 3D-Slicer software-assisted minimally invasive catheterization and minimally invasive soft-channel drainage under CT localization, respectively. The general conditions of the surgery, hematoma clearance rate and laboratory indexes, oxidative stress index and prognosis were compared between the two groups.Results:The intraoperative blood loss, the hospitalizationtimein the 3D-Slicer group were lower than those in the CT group: (81.42 ± 12.33) ml vs. (101.54 ± 11.71) ml, (15.67 ± 3.71) d vs. (17.22 ± 3.52) d; the success rate of one-time successful puncture to preset position in the 3D-Slicer group was higher than that in the CT group: 100.00%(175/175) vs. 81.14%(142/175), there were statistical differences ( χ 2 = 34.26, P<0.05). The hematoma clearance rate after the surgery for 1, 3 and 7d in the 3D-Slicer group were higher than those in the CT group:(87.93 ± 8.54)% vs. (66.43 ± 7.99)%, (92.48 ± 10.31)% vs. (89.52 ± 11.74)%, (96.37 ± 10.22)% vs. (94.30 ± 9.25)%, there were statistical differences( P<0.05). After the surgery for 7 d, the levels of glutathione peroxidase (GSH-Px), superoxide dismutase (SOD) and catalase (CAT) in the 3D-Slicer group were higher than those in the CT group: (121.36 ± 10.59)U/L vs. (109.14 ± 9.05) U/L, (92.80 ± 8.63) μg/L vs. (81.45 ± 9.11) μg/L, (24.64 ± 5.43) U/L vs. (20.84 ± 3.47) U/L; while the level of malondialdehyde (MDA) was lower than that in the CT group: (4.42 ± 0.57)μmol/L vs. (5.19 ± 0.51) μmol/L, there were statistical differences ( P<0.05). After the surgery for 3 months, the rate of favorable prognosis in the 3D-Slicer group was higher than that in the CT group 73.71%(129/175) vs. 62.29%(199/175), there was statistical difference ( χ2 = 5.25, P<0.05). Conclusions:Minimally invasive catheterization based on 3D-Slicer software system in the treatment of HICH can not only improve the clinical efficacy, but also shorten the hospitalization time, reduce intraoperative blood loss, and improve the prognosis.