Retrospective study on the treatment of phalanx fractures with absorbable materials
10.3760/cma.j.cn115455-20210126-00167
- VernacularTitle:可吸收材料内固定处理指骨骨折的回顾性研究
- Author:
Daojun LU
1
;
Chunliang HU
;
Bo WANG
;
Xiaohao KE
;
Guoqiang ZHAO
;
Guoliang ZHANG
Author Information
1. 无锡市惠山区人民医院手足显微外科,无锡 214187
- Keywords:
Fracture fixation, internal;
Finger phalanges;
C-reactive protein;
Interleukin-10;
Adrenocorticotropic hormone
- From:
Chinese Journal of Postgraduates of Medicine
2023;46(2):150-153
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the effect of absorbable material internal fixation in the treatment of phalanx fracture and its effect on the complications related to hypersensitive C-reactive protein (hs-CRP), interleukin-10 (IL-10), adrenocorticotropic hormone (ACTH) and foreign body reaction.Methods:The clinical data of 98 patients with phalangeal fracture in Huishan District People′s Hospital of Wuxi City from January 2018 to January 2020 were divided into absorbable group (49 cases, treated with absorbable material internal fixation) and microplate group (49 cases, treated with minimally invasive plate internal fixation). The rates of excellent and good treatment, operation conditions, serum inflammatory stress response indexes levels before and 1 d and 1 week after surgery were compared, and recovery at 3 and 6 months after surgery, the incidence of complications and the degree of treatment satisfaction were counted.Results:The rates of excellent and good treatmentin the absorbable group were higher than that in the micro plate group: 95.92%(47/49) vs. 81.63%(40/49), χ2 = 5.02, P<0.05. The duration of operation in the absorbable group was longer than that in the microplate group: (43.28 ± 12.18) min vs. (31.29 ± 11.69) min; and the duration of hospital stay, fracture healing time and recovery time were shorter than those in the microplate group: (4.09 ± 1.18) d vs. (6.89 ± 2.12) d, (4.35 ± 1.05) weeks vs. (5.69 ± 1.38) weeks, (4.89 ± 1.10) d vs. (6.20 ± 2.01) d; the differences were statistically significant ( P<0.05). The levels of serum hs-CRP, IL-10 and ACTH in absorbable group were lower than those in microplate group at 1 d and 1 week after surgery ( P<0.05). At 3 and 6 months after surgery, the range of motion of metacarpophalangeal joint in the absorbable group was greater than that in the microplate group, and the loss of grip strength of the healthy side was less than that in the microplate group ( P<0.05). The incidence of complications in absorbable group was lower than that in microplate group: 6.12%(3/49) vs. 20.41%(10/49), χ2 = 4.35, P<0.05. Conclusions:The absorbable material internal fixation can achieve good results in the treatment of phalanx fracture, the postoperative recovery is fast, the incidence of complications is lower.