Application of catheter information platform based on failure mode and effect analysis in preventing central venous catheter-related infection in intensive care unit
10.3760/cma.j.cn211501-20220630-02074
- VernacularTitle:基于失效模式与效应分析的导管信息化平台在预防ICU中心静脉导管相关血流感染中的应用
- Author:
Jiaqing XU
1
;
Minhua MO
;
Yingying GAO
;
Wenting ZHANG
;
Shengfang LI
;
Wenjuan LAI
;
Xiaorong DING
Author Information
1. 北京大学深圳医院ICU,深圳 518000
- Keywords:
Central venous catheter;
Catheter informatization;
Failure mode and effect analysis;
Prevention of infection
- From:
Chinese Journal of Practical Nursing
2023;39(24):1846-1852
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the effect of failure mode and effect analysis (FMEA) based catheter information platform in preventing catheter-related bloodstream infection (CRBSI) in intensive care unit to improve the current status of CRBSI.Methods:In this study, a retrospective cohort study was conducted using the purposive sampling method, and 140 patients with indwelling central venous catheters admitted to the ICU of Peking University Shenzhen Hospital from August to December 2021 were set as the control group; the 140 patients with indwelling central venous catheters admitted to the ICU from January to May 2022 were set as the observation group. The control group used electronic forms to record and manage at the bedside after CRBSI cluster nursing measures were given, and the observation group used the catheter information platform based on FMEA to conduct information management on catheter evaluation and maintenance process after CRBSI cluster nursing measures were given. Compared the implementation rate (6 items), implementation time, qualification rate, and incidence of CRBSI in ICU patients between two groups of ICU nurses.Results:The implementation rate of CRBSI cluster nursing measures among ICU nurses in the observation group: strict hand hygiene by nurses was 87%(122/140), maximum aseptic barrier during puncture was 97%(136/140), aseptic operation during catheter maintenance was 91%(128/140), 75% alcohol disinfection of connectors was 84%(118/140), 24-hour change of infusion lines was 95%(133/140), and timely change of patches/dressings was 89%(125/140), they were greater than those in the control group 70%(98/140), 87%(122/140), 71%(100/140), 61%(86/140), 71%(99/140), 69%(96/140), the differences were statistically significant ( χ2 values were 9.67 to 29.07, all P<0.05); the execution time and qualification rate among ICU nurses in the observation group were (9.11 ± 2.83) minutes and 91.4% (128/140), the control group were (10.00 ± 2.84) minutes and 60.7% (85/140), with statistically significant differences ( t value was -2.64, χ2 values was 36.28, all P<0.05). Conclusions:The FMEA-based catheterization information platform can help enhance the efficiency of the implementation of CRBSI clustering nursing measures by ICU nurses, improve the quality of care, and thus reduce the occurrence of CRBSI, and the feasibility of clinical promotion is high.