Application of hemostatic bandage in wound management after transradial coronary angiography and/or interventional therapy
10.3760/cma.j.cn211501-20230112-00095
- VernacularTitle:止血贴在经桡动脉行冠状动脉造影和/或介入治疗术后伤口管理中的应用
- Author:
Juntao DUAN
1
;
Sai ZHANG
;
Congying LIU
;
Run WANG
;
Yanmin LI
;
Lincheng YANG
;
Yida TANG
;
Sumei TONG
Author Information
1. 北京大学第三医院心内科,北京 100191
- Keywords:
Percutaneous coronary intervention;
Safety;
Comfort;
Hemostatic bandage;
Radial artery wound;
Outcome evaluation
- From:
Chinese Journal of Practical Nursing
2023;39(9):663-669
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the clinical effectiveness of hemostatic bandage on wound safety and comfort after transradial coronary angiography and/or interventional therapy.Methods:This was a experimental study. A total of 400 consecutive patients who underwent transradial coronary angiography and/or interventional therapy in the Department of Cardiology, Peking University Third Hospital from July to October 2022 were enrolled and randomly divided into the hemostatic bandage group and the hemostatic balloon compressor group by the envelope method with 200 cases in each group. The hemostatic bandage group and the hemostatic balloon compressor group were treated with hemostatic bandage and hemostatic balloon compressor as transradial artery hemostatic device, respectively, to observe and compare postoperative hemostatic effect, hemostat use time, complication rate, postoperative pain, the degree of numbness in the finger on the operated side and wristband comfort between the two groups.Results:The hemostatic success rate was 98.5% (197/200) and 99.0% (198/200) in the hemostatic bandage and the hemostatic balloon compressor group, respectively, with no statistical difference ( χ2=0.20, P>0.05). The hemostat use time in the hemostatic bandage group and the hemostatic balloon compressor group was (6.23 ± 0.47) h and (17.01 ± 7.74) h, respectively, and the difference was statistically significant ( t=-19.66, P<0.01). The incidence of complications in the hemostatic bandage group and the hemostatic balloon compressor group was 13.5%(27/200) and 29.5%(59/200), respectively, and the difference was statistically significant ( χ2=8.01, P<0.05). Among the complications, swelling occurred in 21 individuals of the hemostatic bandage group and 54 individuals of the hemostatic balloon compressor group with statistically significant differences ( U=16 689.50, P<0.01). Besides, the hemostatic bandage group was significantly better than the hemostatic balloon compressor group with statistically significant differences in wound pain at immediate postoperative ( U=13 669.50, P<0.01), in finger numbness at immediate postoperative and 1-hour postoperative (immediate postoperative: U=17 838.00, P<0.05; 1-hour postoperative: U=13 342.50, P<0.01), in comfort at immediate postoperative, 4-hours, 8-hours and 12-hour postoperative(immediate postoperative: U=9 966.50, P<0.01; 4-hour postoperative: U=12 851, P<0.01; 8-hour postoperative: U=14 900, P<0.01; 12-hour postoperative: U=15 920, P<0.01). Conclusions:The hemostatic bandage shows better hemostatic effect, shorter compression time, lower complication rate, less wound pain, less numbness of the finger on the operation side, and higher comfort of the wrist band compared to hemostatic balloon compressor after transradial coronary angiography and/or interventional therapy, which is worthy of clinical promotion.