Preliminary study on three-dimensional morphological reconstruction method for external nose defect based on three-dimensional face template.
10.3760/cma.j.cn112144-20230115-00021
- Author:
Ao Nan WEN
1
;
Yong WANG
2
;
Hong Qiang YE
3
;
Zi Xiang GAO
2
;
Yu Jia ZHU
1
;
Qing Zhap QIN
1
;
Hui Zhen HU
4
;
Yun Song LIU
3
;
Yi Jiao ZHAO
1
Author Information
1. Center of Digital Dentistry, Faculty of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
2. Institute of Medical Technology, Peking University Health Science Center, Beijing 100191, China.
3. Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
4. Special Dental Department, Hospital of Stomatology Lanzhou University, Lanzhou 730031, China.
- Publication Type:Journal Article
- From:
Chinese Journal of Stomatology
2023;58(5):414-421
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.