Comparison of ASSR, ABR and 40 Hz AERP Response Thresholds at Different Frequencies and Their Forensic Applications.
10.12116/j.issn.1004-5619.2020.200913
- Author:
Xin-Yuan ZHANG
1
;
Fang-Liang LUO
1
;
Long-Long CHENG
1
;
Yan-He XIONG
1
;
Ji-Hui LIU
1
Author Information
1. Department of Forensic Clinical Medicine, School of Forensic Medicine, China Medical University, Shenyang 110122, China.
- Publication Type:Journal Article
- Keywords:
40 Hz auditory event related potential (40 Hz AERP);
auditory brainstem response (ABR);
auditory steady-state response(ASSR);
forensic medicine;
pure tone audiometry (PTA);
threshold
- MeSH:
Acoustic Stimulation/methods*;
Audiometry, Evoked Response;
Audiometry, Pure-Tone;
Auditory Threshold/physiology*;
Evoked Potentials, Auditory, Brain Stem/physiology*;
Forensic Medicine;
Hearing/physiology*;
Humans
- From:
Journal of Forensic Medicine
2021;37(6):813-816
- CountryChina
- Language:English
-
Abstract:
OBJECTIVES:To explore the relationship between the frequency characteristics and response threshold of auditory steady-state response (ASSR), auditory brainstem response (ABR) and 40 Hz auditory event related potential (40 Hz AERP), and their application values in forensic medicine.
METHODS:Thirty volunteers with normal hearing (60 ears) were selected to perform pure tone audiometry (PTA) threshold and ASSR, ABR and 40 Hz AERP response threshold tests in the standard sound insulation shielding room, and the results were statistically analyzed by SPSS 22.0 software.
RESULTS:At 0.5 kHz and 1.0 kHz frequencies, the correlation between 40 Hz AERP response threshold and PTA threshold was good, which was better than that of ASSR and ABR response threshold. At 2.0 kHz and 4.0 kHz frequencies, the correlation between ASSR and ABR response thresholds and PTA threshold was good, which was better than that of 40 Hz AERP response threshold.
CONCLUSIONS:To evaluate the hearing at 0.5 kHz and 1.0 kHz frequencies, it is recommended to use 40 Hz AERP and ASSR to comprehensively assess the PTA threshold of the subjects. To evaluate the hearing at 2.0 kHz and 4.0 kHz frequencies, ABR and ASSR are recommended to assess the PTA threshold of subjects comprehensively. The combination of ASSR, ABR and 40 Hz AERP can improve the accuracy of hearing function evaluation.