Determination of five pesticides in fishpond by SPE-GC/MS.
- Author:
Da-Wei LIN
;
Yan ZHANG
;
Hong-Lei SUN
;
Wen-Hai LI
;
Kai SHAO
- Publication Type:Journal Article
- MeSH:
Gas Chromatography-Mass Spectrometry/methods*;
Pesticides/isolation & purification*;
Solid Phase Extraction;
Solvents;
Water Pollutants, Chemical/isolation & purification*
- From:
Journal of Forensic Medicine
2015;31(1):41-43
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To establish the solid phase extraction (SPE) with GC/MS technology for fish poisoning cases to determine five pesticides in fishpond.
METHODS:By three solid phase extraction column including Oasis HLB cartridge, Bond Elut C18 and SampliQ C18, the recovery rate was compared to extract and purify five pesticides in fishpond. The effects of different kinds and dosages of eluents on extract rate were also reviewed.
RESULTS:Using Bond Elut C18 as solid phase extraction column and 3 mL benzene as eluent, the linear range of mass concentration of five pesticides in fishpond was 1-50 μg/mL, and the correlation coefficient was 0.996 2-0.999 6. The limit of detection was 3.4-26 μg/L and the recovery was 61.49%-102.48%. The relative standard deviations was less than or equal to 3.01%. CONCLU-SION: With high sensitivity, good accuracy and precision, SPE-GC/MS has simple and quick operation and less solvent. It can be applied to determination of five pesticides in fishpond.