Structural Analysis and Characterization of 4-F-α-PVP Analog 4-F-3-Methyl-α- PVP Hydrochloride.
10.12116/j.issn.1004-5619.2021.311002
- Author:
Hao-Yang WANG
1
;
Jian WU
1
;
Qian ZHANG
1
;
Xin-Feng MIN
1
;
Xiu-Yan LIU
1
;
Yin-Long GUO
1
Author Information
1. Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China.
- Publication Type:Journal Article
- Keywords:
4-F-3-Methyl-α-PVP hydrochloride;
forensic medicine;
high resolution mass spectrometry;
new psychoactive substance;
nuclear magnetic resonance;
structural analysis;
toxicological analysis
- MeSH:
Benzene;
Gas Chromatography-Mass Spectrometry/methods*;
Spectrometry, Mass, Electrospray Ionization;
Chromatography, High Pressure Liquid/methods*
- From:
Journal of Forensic Medicine
2023;39(2):144-150
- CountryChina
- Language:English
-
Abstract:
OBJECTIVES:To identify 1-(4-fluorophenyl)-2-(1-pyrrolidinyl) pentan-1-one (4-F-α-PVP) analog 1-(4-fluoro-3-methyl phenyl)-2-(1-pyrrolidinyl) pentan-1-one (4-F-3-Methyl-α-PVP) hydrochloride without reference substance.
METHODS:The direct-injection electron ionization-mass spectrometry (EI-MS), GC-MS, electrospray ionization-high resolution mass spectrometry (ESI-HRMS), ultra-high performance liquid chromatography-high resolution tandem mass spectrometry (UPLC-HRMS/MS), nuclear magnetic resonance (NMR), ion chromatography and Fourier transform infrared spectroscopy (FTIR) were integrated utilized to achieve the structural analysis and characterization of the unknown compound in the sample, and the cleavage mechanism of the fragment ions was deduced by EI-MS and UPLC-HRMS/MS.
RESULTS:By analyzing the direct-injection EI-MS, GC-MS, ESI-HRMS and UPLC-HRMS/MS of the compound in the samples, it was concluded that the unknown compound was a structural analog of 4-F-α-PVP, possibly with one more methyl group in the benzene ring. According to the analysis results of 1H-NMR and 13C-NMR, it was further proved that the methyl group is located at the 3-position of the benzene ring. Since the actual number of hydrogen in 1H-NMR analysis was one more than 4-F-3-Methyl-α-PVP neutral molecule, it was inferred that the compound existed in the form of salt. Ion chromatography analysis results showed that the compound contained chlorine anion (content 11.14%-11.16%), with the structural analysis of main functional group information by FTIR, the unknown compound was finally determined to be 4-F-3-Methyl-α-PVP hydrochloride.
CONCLUSIONS:A comprehensive method using EI-MS, GC-MS, ESI-HRMS, UPLC-HRMS/MS, NMR, ion chromatography and FTIR to identify 4-F-3-Methyl-α-PVP hydrochloride in samples is established, which will be helpful for the forensic science laboratory to identify this compound or other analog compounds.