Effective Atomic Number based on Energy Dispersive X-Ray (EDX) Analysis and Carbon Hydrogen Nitrogen (CHN) Analysis for Phantom Material in Medical Physics Applications
- Author:
Siti Hajar Zuber
1
;
Nurul Ab. Aziz Hashikin
1
;
Mohd Fahmi Mohd Yusof
2
;
Rokiah Hashim
3
;
Mohd Zahri Abdul Aziz
4
Author Information
- Publication Type:Journal Article
- Keywords: Effective atomic number, Tissue-equivalent phantom, Rhizophora spp
- From:Malaysian Journal of Medicine and Health Sciences 2021;17(No.4):116-121
- CountryMalaysia
- Language:English
- Abstract: Introduction: In medical physics applications, effective atomic numbers are often employed to set apart and specify the interaction of ionizing radiation with matter. Methods: The effective atomic number of soy-lignin bonded with Rhizophora spp. particleboards were analyzed using Energy Dispersive X-ray analysis and Carbon Hydrogen Nitrogen Analyzer. The effective atomic number were compared and recorded with reference to the effective atomic value of water. Results: The result showed that the effective atomic number calculated for adhesive bound Rhizophora spp. samples were close to effective atomic value of water, with 3.34 – 3.47 % differences by using Energy Dispersive X-ray and 6.47 – 6.78 % differences by using Carbon Hydrogen Nitrogen analysis. The result revealed that through Energy Dispersive X-ray method, the effective atomic number was much closer to water compared to Carbon Hydrogen Nitrogen analysis. Conclusion: Despite the availability of hydrogen content in the samples in Carbon Hydrogen Nitrogen analysis, Energy Dispersive X-ray method was much more preferred and gave better result compared to Carbon Hydrogen Nitrogen analysis thus provide a compelling argument for the use of Energy Dispersive X-ray method to measure the effective atomic number of Rhizophora spp. particleboard in medical physics applications.
- Full text:11.2021my1127.pdf