Determination and analysis of monitoring period and measuring duration of personal internal exposure dose
10.13491/j.issn.1004-714X.2023.03.018
- VernacularTitle:内照射个人剂量监测周期及测量时长的确定分析
- Author:
Zheng LU
1
;
Fuping WEN
1
;
Yuqin LI
1
;
Lijiao WANG
1
;
Wenhui XIAO
1
;
Lihua HE
1
;
Yihua XIA
1
Author Information
1. China Institute of Atomic Energy, Beijing 102413 China.
- Publication Type:OriginalArticles
- Keywords:
Internal exposure monitoring;
Monitoring period;
Measurement duration;
Personal dose
- From:
Chinese Journal of Radiological Health
2023;32(3):316-321
- CountryChina
- Language:Chinese
-
Abstract:
Objective To develop a reasonable plan of monitoring personal internal exposure dose. Methods This paper introduced the methods of monitoring the individual dose and direct measurement of three representative radionuclides. Results The maximum monitoring periods were determined according to the radionuclide retention characteristics and the reporting standards and requirements, which were m(1)/m(T/2) ≤ 3 and m(T/2)/m(T) ≤ 3. The lower detection limit of the instrument was derived from the monitoring periods and the annual radionuclide intake limit, which should be lower than the derived method detection limit of the corresponding radionuclide. Then the measuring duration of the instrument that meets the corresponding conditions was derived from the derived method detection limit of the instrument and the maximum monitoring period. Conclusion Our results provide a reference for the formulation of a plan of monitoring personal internal exposure dose.