Determination of trans-1,1,1,4,4,4-hexafluoro-2-butene in workplace air by gas chromatography
- Author:
HU Jia wen CHEN Jia chun YUAN Jing WU Fan RONG Wei feng SHAO Jun li
- Publication Type:Journal Article
- Keywords:
Workplace Air Trans 1 1 1 4 4 4 hexafluoro 2 butene Gas chromatography
- From:
China Occupational Medicine
2022;49(05):582-
- CountryChina
- Language:Chinese
-
Abstract:
Objective - ,,,,,- - -
To establish a gas chromatographic method for the determination of trans 1 1 1 4 4 4 hexafluoro 2
[ - ()] Methods - ()
butene HFO 1366mzz E in workplace air. HFO 1366mzz E in air was directly collected with aluminum foil
, , ,
composite plastic bag separated by dimethylpolysiloxane capillary column detected by flame ionization detector and
Results - () - 3,
quantified with external standard method. The linear range of HFO 1366mzz E was 6.82 68 200.00 mg/m with the
3,
correlation coefficient of 0.999 9. The detection limit and the lower limit of quantitation were 0.59 and 1.98 mg/m respectively.
- - -
The recovery rate was within 95.45% 103.05%. The relative standard deviation of within batch precision and between batch
- - ,
precision were 2.26% 5.07% and 4.09% 6.82% respectively. The samples can be stored at room temperature for at least seven
Conclusion , ,
days. This method is simple to use with a wide linear range low detection limit high accuracy and precision and
- ()
good sample stability. It can be used for the detection of HFO 1366mzz E in the air of workplace