Application of thermoluminescence dosimeter in environmental monitoring of nuclear power plant
10.13491/j.issn.1004-714X.2022.03.007
- VernacularTitle:热释光剂量计在核电厂环境监测中的应用
- Author:
Weizhu ZHANG
1
;
Shuqian LIN
1
;
Dujuan KONG
1
;
Jianhua LIAO
1
;
Gengcheng HUANG
1
;
Ai CHEN
1
Author Information
1. Guangdong Environmental Radiation Monitoring Center, Guangzhou 510300 China.
- Publication Type:OriginalArticles
- Keywords:
Radiation monitoring;
Thermoluminescence;
Dosimeter;
Daya Bay Nuclear Power
- From:
Chinese Journal of Radiological Health
2022;31(3):296-300
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the effect of gaseous effluent from the six generator sets on the radiation level of the surrounding terrestrial environment in Daya Bay Nuclear Power Base after the operation of Ling’ao Nuclear Power plant. Methods The radiation level in the peripheral environment of the Base was monitored using the thermoluminescence dosimeter (TLD). Twenty-five monitoring sites were set around the Base to investigate the variation of radiation level over a long period of time by collecting the TLDs every three months. Results From 2011 to 2020, the annual γ dose rate of the 25 sites ranged from 76.7 to 207.1 nGy/h, with an average value of (123.3 ± 5.7) nGy/h and a relative deviation of 2%-12%. The TLD monitoring and instantaneous measuring results of γ dose rate were consistent with the survey of the State Environmental Protection Administration in the 20th century and the baseline level prior to the operation of the nuclear power plant. Conclusion There are great differences in natural environmental radiation level across the TLD monitoring sites. The overall environmental γ radiation level within 50 km of the nuclear power base remains unchanged. The emission of gaseous effluent from the operation of the nuclear power plant does not have a cumulative impact on the radiation level of surrounding environment.