Establishment of contralateral arteriovenous fistula by using the waste vein on the side of central venous lesion: a case report.
- Author:
Xue Dong BAO
1
;
Ya Xue SHI
1
;
Min YU
1
;
Si Jie LIU
1
;
Lan Hua MI
1
;
Chang WU
1
;
Wen Ping HU
1
Author Information
- Publication Type:Journal Article
- MeSH: Humans; Arteriovenous Shunt, Surgical/adverse effects*; Blood Vessel Prosthesis Implantation; Treatment Outcome; Renal Dialysis; Arteriovenous Fistula
- From: Chinese Journal of Hepatology 2023;39(1):36-38
- CountryChina
- Language:Chinese
- Abstract: Central venous lesion is a difficult problem in the vascular access complications of hemodialysis, which can cause serious clinical symptoms and affect the quality of hemodialysis and life of patients. We established arteriovenous fistula of the contralateral graft blood vessel with the used vein on the diseased side of the central vein of the patient. The arteriovenous fistula of the graft blood vessel was successfully punctured and hemodialysis was performed 2 weeks later. In this way, we not only solved the problem of venous hypertension and subsequent vascular access in the patient, but also reserved more vascular resources.