Correlation of Videodensitometric Scale and Single Photon Emission Computerized Tomography in Assessment of Myocardial Microperfusion
- VernacularTitle:视频密度阶差对比心肌核素灌注扫描评价心肌微灌注的实验研究
- Author:
Xia YANG
;
Yundai CHEN
;
Hongbin LIU
;
Luyue GAI
- Publication Type:Journal Article
- Keywords:
videodensitometric scale, single photon emission computerized tomography, myocardial microperfusion
- From:
Chinese Journal of Rehabilitation Theory and Practice
2010;16(11):1034-1035
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveTo evaluate the feasibility and the value of videodensitometric scale (VDS) in assessing myocardial microperfusion. Methods11 Beagles were embolized small coronary artery with polystyrene microbubble (100 μm). Coronary angiography was performed after the embolization and the VDS was calculated. Single photon emission computerized tomography (SPECT) was also performed after embolization and SPECT scores were also calculated. ResultsVDS after embolization was (15.2±3.8); and SPECT score was (17.6±6.4). VDS correlated negatively with SPECT scores (r=-0.85, P<0.05).ConclusionVDS keeps a closely correlation with SPECT. It can be used to assess myocardial microcirculation in clinical.