Prediction of bloodstream infection pathogens in hematopoietic stem cell transplantation patients by plasma microbial cell-free DNA sequencing
10.3760/cma.j.cn114452-20220722-00430
- VernacularTitle:应用血浆微生物游离DNA测序预测造血干细胞移植患者血流感染病原体
- Author:
Guankun YIN
1
;
Bingyi HAN
;
Hongbin CHEN
;
Shuai MA
;
Hui WANG
Author Information
1. 北京大学医学部医学技术研究院,北京 100191
- Keywords:
Hematopoietic stem cell transplantation;
Bloodstream infection;
Pathogen;
Prediction;
Microbial cell-free DNA sequencing
- From:
Chinese Journal of Laboratory Medicine
2022;45(12):1267-1274
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To predict the pathogens of bloodstream infection (BSI) in hematopoietic stem cell transplantation (HSCT) patients by plasma microbial cell-free DNA (mcfDNA) sequencing with and without additional amplification.Methods:A total of 978 HSCT patients were enrolled in Peking University People′s Hospital from March to July 2021, and the 7 428 blood samples were prospectively collected from pretransplant conditioning period to 4 months after transplantation. The plasma samples were separated and then cryopreserved. According to blood culture results and whether there were plasma samples before BSI onset, twenty-eight HSCT patients with positive blood culture (39 plasma samples within 1-8 days before BSI onset) and 9 HSCT patients with negative blood culture (9 plasma samples) were filtered. The 39 samples were performed with mcfDNA additional and non-additional amplification sequencing, and the 9 samples were only performed with additional amplification sequencing. With the blood culture results as the gold standard, the consistency between the sequencing and the blood culture results was observed. Student t test and Wilcoxon test were used for statistical analysis. Results:Without additional amplification sequencing, only 7 samples sequencing results were consistent with the blood culture results, and the total pathogen detection rate was 17.95% (7/39). The rates within 3 days and 4-8 days were 23.81% (5/21) and 2/18, respectively. The main pathogenic type detected was gram-negative bacteria (5/7). With additional amplification sequencing, the total pathogen detection rate was 59.26% (16/27) and the rate within 3 days was 8/13. The number of gram-positive bacteria detected was elevated (13/16) and the number of additional microorganisms in additional amplification sequencing was increased significantly ( P=0.001 0), compared with non-additional amplification sequencing. Moreover, additional sequencing analysis of 9 samples from patients with negative culture result showed that no pathogen was detected in six samples, and the common Torque teno virus in HSCT patients was detected in only three samples. Conclusion:The pathogen detection rate of plasma mcfDNA additional amplification sequencing was better than that of non-additional amplification sequencing in HSCT patients before BSI onset, especially in the first three days, which has the potential to predict BSI pathogens.