Role of transesophageal echocardiography in the intraoperative monitoring of left ventricular assist device implantation
10.3760/cma.j.cn131148-20220109-00025
- VernacularTitle:经食管超声心动图在左心室辅助装置植入术中的应用价值
- Author:
Shutang REN
1
;
Xiaocheng LIU
;
Zhengqing WANG
;
Shifu WANG
;
Jin LONG
;
Yunzhou HUANG
;
Zhigang LIU
Author Information
1. 泰达国际心血管病医院超声科,天津 300457
- Keywords:
Echocardiography, transesophageal;
Left ventricular assist device;
HeartCon blood pump
- From:
Chinese Journal of Ultrasonography
2022;31(9):746-752
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the clinical value of intraoperative transesophageal echocardiography (TEE) in monitoring left ventricular assist device (LVAD) implantation.Methods:Between March 2019 and November 2021, 23 consecutive patients from TEDA International Cardiovascular Hospital, including 21 cases with dilated cardiomyopathy, 1 case with myocardial noncompaction and 1 case with ischemic cardiomyopathy, underwent HeartCon blood pump, a type of third generation LVAD implantation for severe heart failure. TEE was preformed in all cases before and after cardiopulmonary bypass. The dimensions of left-sided and right-sided cardiac chamber, ventricular function, de-airing, interventricular septal position, inlet cannulae position and the function of device were observed and recorded during LVAD implantation. Paired t test was used for statistical analysis of left-sided and right-sided heart parameters in pre- and post-operative measurements. Results:The left heart was dilated significantly and coexistent with right heart enlargement in some degree before LVAD implantation in total 23 cases. More than moderate mitral regurgitation (MR) in 16 cases and less than moderate MR in 7 cases were present. Mild or trace aortic regurgitation (AR) existed in 13 cases. More than moderate tricuspid regurgitation (TR) in 4 cases and less than moderate TR in 16 cases were observed. Left atrial appendage thrombosis was detected in 2 cases. After LVAD implantation, TEE revealed that the left ventricular end-diastolic diameter reduced significantly (42 mm/m 2 vs 32.8 mm/m 2, P<0.05) and left ventricular ejection fraction increased accordingly (22.2% vs 34.0%, P<0.05). There were no significant differences in right ventricular diameter and fractional area change between pre- and post-operative findings(all P>0.05). The ratio of left ventricular inner diameter to right ventricular inner diameter (2.09 vs 1.69, P<0.05) decreased in total 23 cases after LVAD implantation.Interventricular septal position became neutral position instead of pre-oprative rightward position. The severity of MR decreased in varying degrees in total 23 cases after LVAD implantation. All patients underwent tricuspid valvuloplasty with residual mild regurgitation in 8 cases. Conclusions:HeartCon blood pump can effectively unload the left ventricle with sufficient cardiac output in patients with severe congestive heart failure. TEE plays a major role in the clinical decision making during LVAD implantation, which can evaluate pre-operative cardiac abnormalities, intra-operative air embolism, inlet cannulae position, cannulas patency and cardiac function, especially blood volume status and the balance between double ventricles, which is critical for optimal functioning of the device.