A case of tsutsugamushi disease complicated by multiple organ dysfunction syndrome treated by extracorporeal membrane oxygenation
10.3760/cma.j.cn121430-20220509-00459
- VernacularTitle:体外膜肺氧合治疗恙虫病并多器官功能衰竭1例
- Author:
Shaofeng XU
1
;
Dabin LI
;
Wenjin LI
;
Chengzhang LIU
Author Information
1. 中国澳门特别行政区镜湖医院重症医学科,中国澳门 00853
- Keywords:
Tsutsugamushi disease;
Multiple organ dysfunction syndrome;
Acute respiratory distress syndrome;
Extracorporeal membrane oxygenation
- From:
Chinese Critical Care Medicine
2022;34(10):1095-1098
- CountryChina
- Language:Chinese
-
Abstract:
Tsutsugamushi disease is an acute infectious disease caused by Rickettsia. Occasionally it has been reported in Macau, China. Critical cases are rare. Because the clinical manifestations of tsutsugamushi disease are non-specific and diverse, if not diagnosed and treated in time, the disease may progress to multiple organ dysfunction syndrome (MODS), severe acute respiratory distress syndrome (ARDS), and even death. A patient with tsutsugamushi disease complicated by MODS was admitted to the intensive care unit (ICU) of Kiang Wu Hospital in Macau, China on September 30, 2021. Combined with the history of outdoor activities (exposure to chigger mite larvae), clinical symptoms and signs (characteristic eschar of tsutsugamushi disease was found on the abdominal skin), related laboratory examinations (Weil-Felix test: negative). Diagnosis of tsutsugamushi disease with MODS. After admission, the patient was treated by anti-infection, correction of coagulation dysfunction, tracheal intubation and mechanical ventilation, noradrenalin to maintain blood pressure, continuous renal replacement therapy (CRRT), but the condition didn't improve significantly. We initiated veno-venous ECMO (VV-ECMO), which was initially setted blood flow to 5 L/min (70 mL·kg -1·min -1), rotate speed to 3 500 rpm, fractional concentration of inspired oxygen (FiO 2) to 1.00. Heparin was used as anticoagulant and activated coagulation time (ACT) was kept between 180 and 200 seconds. Meanwhile the speed of fluid removal in CRRT was adjusted. After 9 hours of ECMO support, the oxygenation improved, the blood flow of ECMO was reduced to about 4 L/min (58 mL·kg -1·min -1), rotate speed to 3 000 rpm. The patient's condition improved after 4 days of ECMO treatment and her ECMO flow rate and FiO 2 could be decreased gradually. On hospital day 5, ECMO was removed. Eight days on mechanical ventilation, the patient was successfully weaned and extubated. On day 11 of hospitalization, weaned the CRRT and turned to intermittent hemodialysis. The patient was transferred out of ICU due to her stable condition on the 12th day hospitalization. After that, her spontaneous urine output increased gradually. The functions of various organs returned to normal. After 36 days of hospitalization, she recovered and was discharged.