Application of information-motivation-behavior skill model in functional exercise after after autologous arteriovenous fistula plasty in hemodialysis patients
10.3760/cma.j.cn211501-20220311-00741
- VernacularTitle:基于信息-动机-行为技巧模型的功能锻炼健康教育方案在血液透析患者自体动静脉内瘘成形术后功能锻炼中的应用研究
- Author:
Ping LI
1
;
Yan QU
;
Yan YU
;
Huili ZHAO
Author Information
1. 青岛大学护理学院,青岛 266071
- Keywords:
Hemodialysis;
Arteriovenous fistula;
Information-motive-behavior skills model;
Function exercise
- From:
Chinese Journal of Practical Nursing
2022;38(34):2665-2672
- CountryChina
- Language:Chinese
-
Abstract:
Objective:Health education program based on information-motivation-behavioral skills model (IMB model) was developed, and its application effect in functional exercise after autogenous arteriovenous fistula (AVF) in hemodialysis patients was explored.Methods:Using the convenient sampling method, 100 patients undergoing AVF surgery in hemodialysis center of Qingdao Municipal Hospital from June 2020 to June 2021 were selected as the study objects. The patients were numbered according to the order of visit. The single number was the observation group, and the double number was the control group. There were 50 patients in each group. The control group was given routine AVF function exercise education, and the observation group was given AVF function exercise education based on the IMB model. Patients′ compliance with functional exercise, cephalic vein diameter, fistula maturation time, and the incidence of complications were compared between the two groups.Results:Finally, 49 cases in the control group and 50 cases in the observation group finished the research. The compliance of function exercise of the observation group was 94.0%(47/50), which was higher than 73.5%(36/49) in the control group, and the difference was statistically significant ( χ2=7.70, P<0.05). The maturation time of plasty in the observation group was (5.18 ± 1.14) weeks, shorter than that in the control group (5.94 ± 1.39) weeks, and the difference was statistically significant ( t=2.98, P<0.05). The cephalic vein diameter and blood flow controlled by hemodialysis pump in the observation group were (5.19 ± 0.28) mm and (218.40 ± 24.19) ml/min, respectively, higher than those in the control group (4.99 ± 0.34) mm and (200.41 ± 23.89) ml/min, the differences were statistically significant ( t=-3.21, -3.72, both P<0.05). The incidence of fistula complications in the observation group was 6.0%(3/50), lower than 22.4%(11/49) in the control group, and the difference was statistically significant ( χ2=5.52, P<0.05). Conclusions:The application of IMB model in hemodialysis patients with functional exercise after AVF plasty can effectively improve patients′ compliance, increase the diameter of cephalic vein and the blood flow controlled by dialysis pump, shorten the maturation time of internal fistula, and reduce the incidence of complications of AVF.