Application effect of silica gel stent loading technology in precision microscopic instrument management
10.3760/cma.j.cn211501-20211214-03427
- VernacularTitle:硅胶支架装载技术在精密显微器械管理中的应用效果评价
- Author:
Fenglian CHE
1
;
Weiwei CHEN
;
Liming QIAN
Author Information
1. 上海交通大学医学院附属瑞金医院消毒供应中心,上海 200025
- Keywords:
Sterilization;
Precision microscopic instruments;
Loading;
Cleaning
- From:
Chinese Journal of Practical Nursing
2022;38(26):2028-2032
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To improve the loading technology of precision micro instruments, so as to ensure not only the quality of cleaning and sterilization, but also the safe use of instruments.Methods:From January to March, 2021, 80 sets of precision micro instruments from Sterilization Supply Center, Shanghai Jiao Tong University School of Medicine Affiliated Ruijin Hospital were randomly divided into silica gel pad loading group (group A) and silica gel stent loading group (group B), 40 sets in each group. The cleaning effect, drying effect, loading effectiveness and sterilization wet bag of the instruments in the two groups were compared, and the staff of the disinfection supply center were satisfied with the operation of the loading technology of the instruments in the two groups.Results:The qualified cleaning numbers of the instruments in group A and B were 37 and 39 respectively, and there was no significant difference between the two groups ( χ2 = 1.05, P>0.05). The qualified drying numbers in the group A and B were 29 and 38 respectively, the difference between the two groups was significant ( χ2 = 7.44, P<0.05). The effective number of loading in the group A and B were 30 cases and 39 cases respectively, the difference was significant between the two groups ( χ2 = 8.54, P<0.05). The number of sterilized wet bags in the group A and B were 6 cases and 0 cases respectively, the difference was significant between the two groups ( χ2 = 6.49, P<0.05). The satisfaction of 44 personnel in the disinfection supply center with the operation of loading technology were 36 and 43 respectively, the difference was statistically significant between the two groups ( χ2 = 6.07, P<0.05). Conclusion:Loading precision micro instruments with silica gel stent can not only ensure the cleaning and sterilization quality of instruments, but also make the loading of instruments more safe and stable, greatly improve the working efficiency of instrument treatment and accelerate the turnover efficiency of instruments.