Inter-laboratory comparison analysis of noise measurement in 91 occupational hygiene technical service organizations.
10.3760/cma.j.cn121094-20210514-00250
- Author:
Guo Yong XU
1
;
Ming Zhen LAI
1
;
Dan Ying ZHANG
1
;
Hua YAN
1
;
Mao Sheng YAN
1
;
Bin XIAO
1
Author Information
1. Institate of Physical Factors and Occupational Health, Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment, Guangzhou 510300, China.
- Publication Type:Journal Article
- Keywords:
Inter-laboratory comparison;
Noise;
Occupational health technical service organization;
z-score
- MeSH:
Humans;
Workplace;
Occupational Health Services;
Organizations;
Hygiene;
Workforce;
Noise, Occupational
- From:
Chinese Journal of Industrial Hygiene and Occupational Diseases
2022;40(11):821-825
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To understand the comparability of noise measurement results of various occupational hygiene technical service organizations in Guangdong Province by conducting inter-laboratory comparison of measuring instruments and personnel operation. Methods: In October 2020, the instrument comparison and personnel comparison among 91 occupational hygiene technical service organizations engaged in noise measurement in Guangdong Province were carried out in the form of fixed-point measurement and simulated workplace measurement, and the results were analyzed and evaluated by using the robust z-ratio score. Results: In the instrument comparison, 6 organizations had 1 or 2 outliers in their z-ratio scores, 2 organizations had 2 problematic values in their z-ratio scores, and a total of 8 organizations (accounting for 8.8%) were judged as unqualified; A total of 83 organizations (accounting for 91.2%) with satisfactory z-ratio scores or only one problematic value were judged as qualified. In the personnel comparison, there were 11 organizations with 1 or 2 outliers in the z-ratio score, and 1 organization with 2 problematic values in the z-ratio score. A total of 12 organizations (13.2%) were judged as unqualified and 79 organizations (accounting for 86.8%) with satisfactory z-ratio scores or only one problematic value were judged as qualified. Through comprehensive judgment, 20 organizations (22.0%) were judged as unqualified, and 71 organizations (78.0%) were judged as qualified. There was no statistically significant difference in the qualified rates of instrument comparison results, personnel comparison results and comprehensive evaluation results of non-private organizations and private organizations (P>0.05). There was no significant difference in the qualified rates of instrument comparison results and comprehensive evaluation results of qualified organizations and unqualified organizations (P>0.05), there was significant difference in the qualified rate of personnel comparison results (P<0.05) . Conclusion: The noise measurement results of some occupational health technical service organizations in Guangdong Province are generally comparable. To carry out inter-laboratory comparison of noise instrument performance and personnel operation ability of occupational hygiene technical service organizations, can comprehensively evaluate the testing process of each organization and find out the problems existing in each organization.