Correlations among parameters of iTrace, Pentacam and lens opacities classification system Ⅲ in lens opacity assessment
10.3980/j.issn.1672-5123.2023.1.29
- VernacularTitle:iTrace和Pentacam及LOCSⅢ参数在晶状体混浊程度评估中的相关性
- Author:
Jia-Wei LUO
1
,
2
;
Min JI
1
,
2
;
Miao-Miao QIN
1
,
2
;
Peng-Fei LI
1
,
2
;
Huai-Jin GUAN
1
,
2
Author Information
1. Eye Institute, Affiliated Hospital of Nantong University
2. Medical School of Nantong University, Nantong 226001, Jiangsu Province, China
- Publication Type:Journal Article
- Keywords:
Pentacam 3D anterior segment analysis system;
lens opacities classification system Ⅲ(LOCSⅢ);
iTrace visual function analyzer;
age-related cataract
- From:
International Eye Science
2023;23(1):147-152
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To analyze the correlations among parameters from iTrace visual function analyzer, Pentacam 3D anterior segment analysis system and lens opacities classification system(LOCS)Ⅲ in the assessment of lens opacity of age-related cataract(ARC)patients.METHODS: A prospective cross-sectional study. A total of 104 ARC patients(104 eyes)in the department of ophthalmology of our hospital from May to August, 2021 were included. The cataracts of patients were graded based on LOCSⅢ using a slit-lamp. Opacity map grade(OMG)and dysfunctional lens index(DLI)were obtained by iTrace. Pentacam nucleus staging(PNS)and Scheimpflug images of lenses were acquired by Pentacam. The regional integrated density(IntDen)of Scheimpflug images was obtained by ImageJ. The normality and correlations of parameters were analyzed by SPSS 26.0.RESULTS: All the parameters were normally distributed except 3mm IntDen and IntDen of 6mm posterior subcapsular region. PNS positively correlated with nuclear color(NC)and nuclear opalescence(NO)(r=0.521, 0.440, all P<0.01). The 3mm IntDen positively correlated with NC and NO(rs=0.459, 0.450, all P<0.01). IntDen of 3mm nucleus region positively correlated with NC and NO(r=0.539, 0.543, all P<0.01). IntDen of 3mm posterior subcapsular region was negatively correlated with NC and NO(r=-0.315, -0.321, all P<0.01). 6mm IntDen positively correlated with NC and NO(r=0.321, 0.288, all P<0.01). 3mm DLI negatively correlated with NC, NO, and posterior subcapsular cataract(PSC)(r=-0.257, -0.234, -0.282, all P<0.01). 6mm DLI negatively correlated with NC, NO, PSC(r=-0.247, -0.304, -0.227, all P<0.05). 3mm OMG positively correlated with CC and PSC(r=0.268, 0.333, all P<0.01), and 6mm OMG positively correlated with CC and PSC(r=0.275, 0.245, all P<0.05). 3mm DLI negatively correlated with PNS and IntDen of 3mm nucleus region(r=-0.217, -0.197, all P<0.05).CONCLUSION:Each lens opacity assessment system had its own advantages. Taking all parameters into comprehensive consideration is conducive to objectively eraluate the opacity degree of each area of the lens and provide references for clinical work.