Clinical application of bipolar tweezers-clamp for hepatic parenchymal transection.
10.3760/cma.j.cn112139-20210629-00280
- Author:
Shu You PENG
1
;
Cong Yun HUANG
2
;
Jian Hua ZHU
2
;
Li Ming WU
2
;
Wen Ying LIU
2
;
Yong TAN
2
;
Zai Xing OUYANG
2
;
Hao SONG
2
Author Information
1. Department of General Surgery,the Second Affiliate Hospital,Zhejiang University Medical School,Hangzhou 310009,China.
2. Department of Hepatobiliary Surgery,Yuebei People's Hospital Affiliated to Shantou University Medical College,Shaoguan 512026,China.
- Publication Type:Journal Article
- MeSH:
Blood Loss, Surgical;
Carcinoma, Hepatocellular/surgery*;
Female;
Hemorrhage;
Hepatectomy/methods*;
Humans;
Hypertension, Portal/surgery*;
Liver Failure;
Liver Neoplasms/surgery*;
Male;
Retrospective Studies;
Treatment Outcome
- From:
Chinese Journal of Surgery
2022;60(5):449-453
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To investigate the clinical value of the bipolar tweezers-clamp for the hepatic parenchymal transection in the resection of hepatocellular carcinoma. Methods: From January 2020 to January 2021,63 patients with the hepatocellular carcinoma for hepatectomy at Department of Hepatopancreatobiliary Surgery,Yuebei People's Hospital Affiliated to Shantou University Medical College were analyzed retrospectively.According to the different instruments used in the hepatic parenchymal transection,the patients were divided into bipolar tweezers-clamp group and ultrasonic scalpel group.There were 32 patients in bipolar tweezers-clamp group,with age of (55.5±10.5)years(range:37 to 78 years),including 22 males and 10 females,tumor size was (6.0±3.4)cm(range:2.4 to 13.4 cm). There were 6 patients with portal vein tumor thrombus and 5 patients with portal hypertension. There were 31 patients in ultrasonic scalpel group,with aged(57.8±10.1)years(range:37 to 79 years),including 27males and 4 females,tumor size was(7.9±5.1)cm(range: 2.4 to 21.3 cm),3 patients with portal vein tumor thrombus and 2 patients with portal hypertension. The preoperative baseline data,operation time,blood loss,postoperative liver function and the complications were compared between two groups using t test,χ2 test and Fisher exact probabilityrespectively. Results: The operation was successfully completed in both groups.Compared with the ultrasonic scalpel group,the operation time was significantly shorter((219.3±76.4)minutes vs.(294.0±100.8)minutes,t=-3.322,P=0.002),the blood loss was less((250(475)ml vs. 500(1 050)ml,t=-2.307,P=0.026),the concentrate red blood cells transfusion volume was less(0.92(0.88)U vs. 2.32(4.00)U,Z=-1.987,P=0.047) in the bipolar tweezers-clamp group.The postoperative serum ALB level was higher in the bipolar tweezers-clamp group than that in the ultrasonic scalpel group((33.5±6.1)g/L vs. (29.5±4.2)g/L,t=3.226,P=0.020) on postoperative day 1;((35.7±4.5)g/L vs.(30.1±3.2)g/L,t=5.575,P<0.01) on postoperative day 3;((33.2±3.7)g/L vs. (31.0±4.4)g/L,t=3.020,P=0.004) on postoperative day 7. There was no significant difference in serum ALT,TBIL and PT level between the two groups(all P>0.05).No postoperative bile leakage occurred in both groups.The postoperative complications occurred in 8 cases(25.0%)in the bipolar tweezers-clamp group,including liver failure in one,and in 11 cases(35.5%)in the ultrasonic scalpel group,including liver failure in two(P>0.05). Conclusion: The bipolar tweezers-clamp is a safe and reliable method for the hepatic parenchymal transaction,which is quick and less bleeding during the hepatic resection.