Value of (11)C-PiB PET/MRI in the evaluation of organ involvement in primary systemic light chain amyloidosis.
10.3760/cma.j.issn.0253-2727.2022.04.009
- Author:
Ya Dan WANG
1
;
Ya Ying YANG
1
;
Ying Ying WU
1
;
Chun Yan SUN
1
Author Information
1. Institute of Hematology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
- Publication Type:Journal Article
- Keywords:
Amyloid;
Organ;
Positron-emission tomography;
Systemic light chain amyloidosis
- MeSH:
Amyloidosis/diagnostic imaging*;
Aniline Compounds;
Humans;
Magnetic Resonance Imaging;
Positron-Emission Tomography;
Retrospective Studies;
Stroke Volume;
Ventricular Function, Left
- From:
Chinese Journal of Hematology
2022;43(4):316-322
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To analyze the value of (11)C-PiB PET/MRI for evaluating organ involvement in patients with primary light chain amyloidosis (pAL) . Methods: The clinical data of 20 patients with pAL and 3 healthy volunteers from January 2019 to October 2021 were retrospectively analyzed. The correlation between the organ involvement evaluated by clinical standards and PET/MRI was compared. The relationship between cardiac-related biological indicators, disease stage, and the maximum standardized uptake value (SUVmax) were analyzed. The relationship between 24-hour urinary protein quantification and kidney SUVmax was analyzed. Results: ①In 20 patients (18 newly diagnosed patients and 2 non-newly diagnosed patients) ,(11)C-PiB positive uptake was observed in the heart (15 patients, 75%) , lung (8 patients, 40%) , bone marrow (10 patients, 50%) , muscle (10 patients, 50%) , tongue muscle (7 patients, 35%) , thyroid (6 patients, 30%) , salivary gland (4 patients, 20%) , spleen (2 patients, 10%) , and stomach wall (1 patient, 5%) . ②Organ involvement on (11)C-PiB PET/MRI showed good correlations with the clinical evaluation criteria for the heart and bone marrow. The positive rate of PET/MRI evaluation in the lung, spleen, gland, muscle, and tongue muscle was significantly higher than the clinical criteria. However, (11)C-PiB PET/MRI has limitations in the evaluation of the nervous system and fat tissue. ③To analyze the relationship between cardiac-related biological indexes and the SUVmax of the heart in 13 newly diagnosed patients. Patients with left ventricular ejection fraction (LVEF) <50% and interventricular septal thickness (ISV) ≥1.2 cm showed a higher SUVmax than patients with LVEF ≥50% and ISV<1.2 cm (P<0.05) .There are significant differences in the SUVmax of the heart between the Mayo2004 stage and the Mayo2012 stage. The later the disease stage, the higher the SUVmax (P<0.05) . The SUVmax of the heart was positively correlated with cardiac troponin I (cTnI) and N-terminal pro-brain natriuretic peptide (NT-proBNP) (P<0.01) .There was no significant correlation between renal SUVmax and 24-hour urine protein (P>0.05) . Conclusion: Whole body (11)C-PiB PET/MRI, as a visualization system of amyloid protein, is used to qualitatively evaluate organ involvement, which can improve the level of early non-invasive diagnosis. Whole body (11)C-PiB PET/MRI can be used to perform quantitative evaluation of organ levels, especially the heart, which is expected to evaluate organ function and predict disease prognosis more accurately.