Comparison of setup errors in supraclavicular regions of lung and esophageal cancer treated with radiotherapy
10.3760/cma.j.cn113030-20210622-00236
- VernacularTitle:肺癌和食管癌两种不同放疗体位锁骨上区摆位误差比较
- Author:
Bao WAN
1
;
Xu YANG
;
Fukui HUAN
;
Yanxin ZHANG
;
Xin FENG
;
Yu ZHAO
;
Yingwei WU
;
Songsong GENG
;
Kuo MEN
;
Zhouguang HUI
Author Information
1. 国家癌症中心/国家肿瘤临床医学研究中心/中国医学科学院北京协和医学院肿瘤医院放疗科,北京 100021
- Keywords:
Setup error;
Supraclavicular region;
Lung neoplasm/three-dimensional radiotherapy;
Esophageal neoplasm/three-dimensional radiotherapy
- From:
Chinese Journal of Radiation Oncology
2022;31(3):272-276
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the setup errors in the supraclavicular regions of two different postures (arms placed on each side of the body, namely the body side group; arms crossed and elbows placed above forehead, namely the uplifted group) using the chest and abdomen flat frame fixation device in lung and esophageal cancer.Methods:Clinical data of patients with stage Ⅰ to Ⅳ lung or esophageal cancer who received three-dimensional radiotherapy with chest and abdomen flat frame fixation device in our institution from November 2020 to April 2021 were retrospectively analyzed. The setup errors of two postures were compared.Results:A total of 56 patients were included, including 31 patients (55%) in the body side group and 25 patients (45%) in the uplifted group. A total of 424 CBCTs were performed in the whole group. The overall setup errors in the X, Y and Z directions were similar in both groups ( P>0.05). The setup errors of sternoclavicular joint in the X and RZ directions in the body side group were significantly smaller than those in the uplifted group [(0.163±0.120) cm vs. (0.209 ±0.152) cm, P=0.033; 0.715°±0.628° vs. 0.910°±0.753°, P=0.011]. The setup errors of acromioclavicular joint in the Y, Z and RZ directions in the body side group were significantly smaller than those in the uplifted group [(0.233±0.135) cm vs. (0.284±0.193) cm, P=0.033; (0.202±0.140) cm vs. (0.252±0.173) cm, P=0.005; 0.671°±0.639° vs. 0.885°±0.822°, P=0.023]. The margins of target volume for setup errors were smaller in the X (0.45 cm vs. 0.54 cm) and Y (0.54 cm vs. 0.65 cm) directions of the sternoclavicular joint, as well as in the Y (0.59 cm vs. 0.78 cm) and Z directions (0.53 cm vs. 0.72 cm) of the acromioclavicular joint in the body side group. Conclusions:For lung and esophageal cancer patients requiring supraclavicular irradiation, the body side group yields smaller setup errors and corresponding margins of target volume than the uplifted group. In clinical practice, it is necessary to take comprehensive consideration of the accuracy of radiotherapy and additional radiation of the limbs to select appropriate posture.