Contrast-enhanced ultrasound combined with Ovarian-Adnexal Reporting and Data System US risk stratification and management system for diagnosis of adnexal masses
	    		
		   		
		   			 
		   		
	    	
    	 
    	10.3760/cma.j.cn131148-20211015-00739
   		
        
        	
        		- VernacularTitle:超声造影联合卵巢-附件超声报告和数据风险分层系统的临床应用价值
- Author:
	        		
		        		
		        		
			        		Qingjuan WANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Qian LIANG
			        		
			        		;
		        		
		        		
		        		
			        		Jian ZHENG
			        		
			        		;
		        		
		        		
		        		
			        		Siliang KANG
			        		
			        		;
		        		
		        		
		        		
			        		Liling HUANG
			        		
			        		
		        		
		        		
		        		
    Author Information Author Information
 
			        		
			        		
			        			1. 深圳市龙岗区第三人民医院超声科,深圳 518115
 
 
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Contrast-enhanced ultrasound;
			        		
			        		
			        		
				        		Ovarian-adnexal mass;
			        		
			        		
			        		
				        		Ovarian-Adnexal Reporting and Data System;
			        		
			        		
			        		
				        		Differentiation
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2022;31(3):220-225
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To explore the value of contrast-enhanced ultrasound (CEUS) combined with Ovarian-Adnexal Reporting and Data System (O-RADS US) risk stratification and management system in differential diagnosis of ovarian-adnexal mass.Methods:Fifty-six patients with ovarian-adnexal mass who received transabdominal transvaginal ultrasound and CEUS in the Third People′s Hospital of Longgang District from September 2018 to January 2021 were enrolled. The images were classified by O-RADS US and diagnosed by CEUS by experienced and senior radiologist. On the basis of O-RADS US classification, the enhancement time, enhancement level and enhancement mode of CEUS were combined to upgrade or degrade the classification results of O-RADS US. The diagnostic accuracy was assessed using ROC curve analysis, the area under the ROC curve (AUC) was calculated. The reproducibility of O-RADS US was assessed by another senior radiologist.Results:The AUC of O-RADS US for diagnosing benign and malignant ovarian-adnexal masses was 0.844(0.722, 0.927), the AUC of CEUS was 0.833(0.710, 0.920), the AUC of O-RADS US combined with CEUS was 0.940(0.842, 0.986) (compared with O-RADS US, P=0.020; compared with CEUS, P=0.031). The intra-class correlation coefficient (ICC) was 0.897(0.824, 0.940) for O-RADS US. Conclusions:CEUS combined with O-RADS US classification can effectively improve the diagnostic efficiency for benign and malignant ovarian-adnexal masses.