Effects of biofeedback dialysis mode of blood volume monitoring on cardiac function in the maintenance hemodialysis patients with intra-dialytic hypotension
10.3760/cma.j.cn431274-20210714-00752
- VernacularTitle:生物自动反馈式血容量监测模式干预血液透析中低血压对维持性血液透析患者心功能的影响
- Author:
Qing HUA
1
;
Qiang CHEN
;
Hongmei WANG
;
Yuezhi WANG
Author Information
1. 南京医科大学姑苏学院,苏州市立医院,南京医科大学附属苏州医院肾内科,南京 215008
- Keywords:
Hemodialysis;
Hypotension;
Blood volume monitoring;
Echocardiography
- From:
Journal of Chinese Physician
2022;24(4):551-555
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To discuss the effects of biofeedback dialysis mode of blood volume monitoring on cardiac function in the maintenance hemodialysis (MHD) patients with intra-dialytic hypotension (IDH).Methods:40 patients who underwent maintenance hemodialysis in Suzhou Hospital Affiliated to Nanjing Medical University from September 2018 to December 2020 and had IDH for many times were selected. They were divided into standard dialysis (SHD) group and biofeedback dialysis mode of blood volume monitoring (BVM) group, with 20 cases in each group. In the first 12 weeks of the first stage, the patients in both groups were treated with standard dialysis, and in the second 12 weeks, they were treated with maintenance hemodialysis according to standard dialysis and biofeedback dialysis mode of blood volume monitoring. The incidence of IDH and the changes of blood pressure before and after dialysis, body weight, ultrafiltration volume, B-type brain natriuretic peptide (BNP), left ventricular ejection fraction (LVEF), left ventricular end diastolic diameter (LVEDD), left ventricular posterior wall thickness (LVPW), inlet ventricular septal defect (IVSD), mitral valve flow spectrum E/A value (E/A) and left ventricular mass index (LVMI) were observed.Results:(1) In the second stage of treatment, the number of IDH requiring nursing intervention in BVM group was significantly lower than that in SHD group ( P<0.05). (2) The difference of blood pressure change in BVM group during the second stage of treatment was significantly lower than that in the first stage and SHD group ( P<0.05). (3) In the second stage of treatment, the ultrafiltration volume of patients in BVM group was significantly higher than that in the first stage, and the BNP and body weight were significantly lower than that in the first stage (all P<0.05). However, the body weight, BNP and ultrafiltration volume of patients in SHD group had no significan change in the two stages of treatment (all P>0.05). (4) After treatment, the LVID, LVPW, IVSD and LVMI in BVM group were significantly lower than those before treatment, and LVEF and E/A were significantly higher than those before treatment (all P<0.05). However, there was no significant change in echocardiographic indexes in SHD group before and after treatment (all P>0.05). Conclusions:The biofeedback dialysis mode of blood volume monitoring can significantly reduce the occurrence of IDH, and this dialysis mode can effectively improve the cardiac function of MHD patients with hypotension.