Tc-99m MIBI and Tl-201 Uptake in a Thymic Carcinoma.
- Author:
In Young HYUN
1
Author Information
1. Department of Nuclear Medicine, Inha University College of Medicine, Inchon, Korea. iyhyun@inha.ac.kr
- Publication Type:Brief Communication
- Keywords:
Tc-99m MIBI;
Tl-201/technetium subtraction;
Parathyroid scintigraphy;
Thymic carcinoma
- MeSH:
Parathyroid Glands;
Radionuclide Imaging;
Thymoma*
- From:Korean Journal of Nuclear Medicine
2003;37(4):260-261
- CountryRepublic of Korea
- Language:English
-
Abstract:
Tc-99m methoxyisobutylisonitrile (MIBI) and Tl-201/technetium subtraction scintigraphy have been used for localization of abnormal parathyroid gland. The uptake mechanism of tracers has been postulated to be increased cellular density and vascularity, or dependent on the presence of mitochondria-rich cells. However, the uptake of these tracers was not specific for abnormal parathyroid gland. The author report a case of thymic carcinoma that would have been mistaken for carcinoma of parathyroid because of Tc-99m MIBI and Tl-201 uptake.