Clinical efficacy of screw placement assisted with the 3D printing pre-installed screw channel model in the single complete segmented congenital hemivertebrectomy
10.3760/cma.j.cn101070-20210203-00155
- VernacularTitle:3D打印预置钉道模型辅助置钉治疗单发性完全分节型先天性半椎体的临床疗效
- Author:
Xin′ge SHI
1
;
Yuepeng SONG
;
Weiran HU
;
Haohao MA
;
Shuai XING
;
Yanzheng GAO
Author Information
1. 河南省人民医院,河南大学人民医院,郑州大学人民医院脊柱脊髓外科,郑州 450003
- Keywords:
Scoliosis;
Kyphosis;
3D printing;
Hemivertebra resection
- From:
Chinese Journal of Applied Clinical Pediatrics
2022;37(3):200-204
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the clinical effect of the 3D printing pre-installed screw channel model in assisting screw placement of single complete segmented congenital hemivertebrectomy.Methods:Clinical data of 13 children treated with single complete segmented congenital hemivertebrectomy in the Department of Spine and Spinal Surgery of Henan Provincial People′s Hospital from August 2016 to January 2019 were retrospectively analyzed.Among them, there were 5 males and 8 females with the mean age of 9.9 (5-14) years.Categorized by the lesion location, 3 cases were located at T 9, 2 cases at T 10, 5 cases at T 11, 1 case at T 12, and 2 cases at L 1.During the operation, the 3D printing pre-installed screw channel model was used to assist the placement of pedicle screws.The accuracy of screw placement was assessed by the postoperative CT.All children were routinely examined by full-length anterior and lateral X-ray of spine in the standing position before and after surgery to measure the Cobb angles at the coronal and sagittal view.Furthermore, the correction rate of scoliosis and kyphosis after surgery and during follow-up was also calculated.The One-Way repeated measures ANOVA was used to compare the Cobb angle of scoliosis and kyphosis before surgery, after surgery and during follow-up. Results:A total of 85 pedicle screws were placed in 13 children, with the accuracy rate of screw placement of 95.3%.The mean surgery time and intraoperative blood loss were (216.9±28.3) min, and (478.5±132.6) mL, respectively.Scoliosis Cobb was corrected from (57.1±12.7)° to (12.7±4.7)° with a correction rate of (78.4±5.9)%, which was (14.2±7.0)° at the last follow-up.Kyphosis angle was corrected from (46.2±8.4)° to (13.2±4.4)° with a correction rate of (72.6±7.0)%, which was (14.0±3.4)° at the last follow-up.None of the children had serious complications like vascular and nerve damage.The mean postoperative follow-up was 12.3 (6-18) months.No significant loss of angle was detected during the follow-up period.There were significant differences in the lateral and kyphotic angles after surgery and during follow-up compared with preoperative ones (all P<0.05). No significant difference was detected between the postoperative lateral and kyphotic angles and those at the last follow-up (all P>0.05). Conclusion:The 3D printing pre-installed screw channel model used to assist screw placement of single complete segmented congenital hemivertebrectomy can improve the precision of screw placement and the orthopedic effect on lateral kyphosis.