Effect on postoperative visual quality with modified ABC design aspheric IOL implantation of cataract patients
10.3980/j.issn.1672-5123.2022.7.06
- VernacularTitle:改良ABC设计的非球面IOL植入对白内障患者术后视觉质量的影响
- Author:
Hong-Gang WANG
1
,
2
,
3
;
Juan LUO
1
,
2
,
3
;
Yi-Ping HU
1
,
2
,
3
;
Yu-Qi LIU
1
,
2
,
3
;
Jin-Song ZHANG
1
,
2
,
3
;
Jing WANG
1
,
2
,
3
Author Information
1. Department of Ophthalmology, Anshan Hospital of Traditional Chinese Medicine, Anshan 114000, Liaoning Province, China
2. Department of Ophthalmology, the Fourth Affiliated Hospital of China Medical University
3. the Key Lenticular Laboratory of Liaoning Province, Shenyang 110005, Liaoning Province, China
- Publication Type:Journal Article
- Keywords:
cataract;
visual quality;
intraocular lens(IOL);
aspheric balanced curve(ABC)
- From:
International Eye Science
2022;22(7):1097-1102
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To evaluate the visual quality of patients after modified design aspheric balance curve(ABC)with intraocular lens(IOL)implantation, and to analyze the influencing factors of clinical IOL selection and guide the patient's IOL selection plan. METHODS: A prospective case-control study was conducted in 67 patients(74 eyes)with simple cataract underwent phacoemulsification and foldable aspheric IOL implantation, and 23 eyes in the observation group were implanted with modified design IOL(HOYA Vivinex XY1 group), the control group was implanted with 51 eyes of traditional design IOL(Tecnis ZCB00 group with 27 eyes, IQ SN60WF group with 24 eyes). The uncorrected visual acuity, the best corrected visual acuity, total ocular spherical aberration(SA)and coma under different pupil diameters(3, 4, 5, 6mm), and different pupil diameters(3, 4, 5mm)were measured 1wk and 1mo after operation, the modulation transfer function(MTF)curve, objective scattering index(OSI), intraocular scattered light value Log(s)and contrast sensitivity were obtained. Statistical analysis was performed on the obtained data.RESULTS: The uncorrected visual acuity and best corrected visual acuity at 1wk and 1mo after operation in the three groups were significantly improved compared with those before operation, there was no significant difference among groups(P>0.05). The difference of total ocular spherical aberration was statistically significant among the three groups with 5 and 6mm pupil diameter 1wk after operation(P=0.045, 0.037)and there were differences among three groups in pupil diameter of 6mm at 1mo after operation(P=0.042). Comparing the total ocular coma aberration, there were differences among the three groups at 1wk and 1mo after the operation at the pupil diameter of 5 and 6 mm(P<0.05). With the increase of pupil diameter at 1wk and 1mo after operation, the total ocular spherical aberration in the HOYA Vivinex XY1 group was lower than that in the other two groups. The MTF values of the Vivinex XY1 group were higher than those that of the control group at each spatial frequency, there was no significant difference among groups(P>0.05), and there were no statistical differences in objective scattering index, intraocular scattered light value Log(s)and contrast sensitivity among the three groups(P>0.05).CONCLUSION:The improved design of the modified Vivinex IOL can reduce the total ocular spherical aberration and coma, improve the visual quality, and provide a new method for the selection of aspheric IOL.