Treatment of abduction and insertion femoral neck fracture with closed reduction technique.
10.12200/j.issn.1003-0034.2022.04.012
- Author:
Qiu-Liang ZHU
1
;
Mao-Hua YAN
1
;
Bin XU
1
;
Jun MA
1
;
Tao SONG
1
Author Information
1. Department of Orthopaedics, the People's Hospital of Anji, Huzhou 313300, Zhejiang, China.
- Publication Type:Journal Article
- Keywords:
Closed fracture reduction;
Femoral neck fractures;
Fracture fixation, internal;
Surgical procedures, minimally invasive
- MeSH:
Adult;
Bone Wires;
Female;
Femoral Neck Fractures/surgery*;
Fracture Fixation, Internal/methods*;
Humans;
Male;
Middle Aged;
Retrospective Studies;
Treatment Outcome
- From:
China Journal of Orthopaedics and Traumatology
2022;35(4):357-360
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To explore feasibility of closed reduction technique under monitoring of C-arm and three screws in the fixation of abduction and insertion femoral neck fracture.
METHODS:Seventeen patients with abduction and insertion femoral neck fracture operated from January 2014 to December 2019 were analyzed retrospectively, including 10 males and 7 females, aged from 21 to 59(42.09±7.30) years old. According to preoperative X-ray and CT data, angle of retroversion and abduction displacement of femoral head were determined. Two 2 mm diameter Kirschner wires crossed and gently knocked into the bone of the acetabular roof from outside and front of femoral head. The proximal fracture segment was fixed on the acetabulum. Under the monitoring of C-arm, lower limb (distal fracture segment) was gradually rotated inward and retracted against direction of fracture displacement, three cannulated screws were used for internal fixation after anatomical reduction of the distal fracture end and the proximal fracture end. Garden index was evaluated, postoperative complications were observed, and Harris functional score was performed.
RESULTS:All 17 cases of femoral neck fracture with abduction and insertion were successfully completed closed reduction and internal fixation. The operation time was 36 to 68(43.87±7.63) min and intraoperative bleeding was 15 to 50(28.36±5.93) ml. The quality of fracture reduction was evaluated by garden index during operation. There were 12 cases of anatomical reduction, 5 cases of acceptable reduction, and no cases of unsuccessful reduction were changed to open reduction. 17 cases were followed up for 3 to 41(27.5±8.4) months. There were no complications such as femoral head necrosis, fracture nonunion, hip impingement and femoral neck shortening. MR examination showed no femoral head necrosis and articular cartilage injury. Two years after operation, Harris score of hip joint was excellent in 13 cases and good in 4 cases.
CONCLUSION:Closed reduction and three screws internal fixation can obtain good anatomical reduction rate and therapeutic effect in the treatment of abduction and insertion femoral neck fracture.