Case control study on the application of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with special-shaped plate.
10.12200/j.issn.1003-0034.2021.09.004
- Author:
Liang ZHOU
1
;
Qi-Ping CHU
1
;
Hua-Jun YU
1
Author Information
1. Tongde Hospital of Zhejiang Province, Hangzhou 310012, Zhejiang, China.
- Publication Type:Journal Article
- Keywords:
Calcaneus;
Case-control studies;
Fracture fixation, internal;
Open fracture reduction
- MeSH:
Adolescent;
Adult;
Aged;
Bone Plates;
Calcaneus/surgery*;
Case-Control Studies;
Female;
Fracture Fixation, Internal;
Fractures, Bone/surgery*;
Humans;
Male;
Middle Aged;
Treatment Outcome;
Young Adult
- From:
China Journal of Orthopaedics and Traumatology
2021;34(9):808-813
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To compare clinical effects of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with profitated plate.
METHODS:From April 2015 to April 2019, 60 patients with complex calcaneal fractures were treated with open reduction and heteromorphic plate internal fixation, and were divided into experiment group and control group by implant bone substitutes, and 30 patients in each group. In experiment group, there were 21 males and 9 females aged from 18 to 71 years old with an average of (36.85±7.42) years old;19 patients were classified to type Ⅲ and 11 patients were type Ⅳ according to Sanders classification;implanted with artificial bone. While in control group, there were 23 males and 7 females aged from 20 to69 years old with an average of (37.26±7.38) years old;18 patients were classified to type Ⅲ and 12 patients were type Ⅳ according to Sanders classification; implanted with autogenous bone. Operation time, intraoperative blood loss, drying time of incision, fracture healing time and complications were compared between two groups, changes of preoperative and postoperative Böhler angle and Gissane angle were also compared, and Maryland scoring was applied to evaluate recovery of affected foot.
RESULTS:Both of two groups were followed up from 3 to 15 months with an average of (10.15±2.67) months. Operation time and intraoperative blood loss in experiment group were (89.32±12.43) min, (101.64±5.13) ml, respectively;while in control group were (112.45±13.82) min, (119.01±5.26) ml, respectively;and there were statistical difference between two groups (
CONCLUSION:Artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with irregular plate have similar function in promoting fracture healing, drying time of incision, fracture healing time and complications, while artificial bone has better effects in reducing intraoperative blood loss, shorten operation time.