Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report
10.4047/jkap.2021.59.4.478
- Author:
Sang Woo HYUN
1
;
Richard LEESUNGBOK
;
Suk Won LEE
;
Young Eun CHO
Author Information
1. Kyung Hee University School of Dentistry, Department of Biomaterials & Prosthodontics, Kyung Hee University Dental School Hospital at Gangdong, Seoul, Republic of Korea
- Publication Type:CASE REPORT
- From:The Journal of Korean Academy of Prosthodontics
2021;59(4):478-486
- CountryRepublic of Korea
- Language:English
-
Abstract:
This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.