Carbon monoxide poisoning-induced type 1 Brugada electrocardiographic pattern
- Author:
Youngmo CHO
1
;
Seok Ran YEOM
;
Suck Ju CHO
;
Byung Kwan BAE
;
Dae Sup LEE
;
Tae Gyu HYUN
;
Jinhee AHN
;
Il Jae WANG
Author Information
1. Department of Emergency Medicine, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
- Publication Type:Case Report
- From:Journal of the Korean Society of Emergency Medicine
2021;32(5):480-484
- CountryRepublic of Korea
- Language:English
-
Abstract:
Carbon monoxide (CO) can cause a variety of electrocardiogram (ECG) changes. The Brugada ECG patterns are very rare in CO poisoning cases. We detected a patient with a CO-induced type 1 Brugada ECG pattern with chest pain. The panel genetic test and echocardiogram revealed normal findings. The Brugada phenocopy gradually improved over 3 days. We reviewed the literature and suggested possible mechanisms.