Evaluation of Three Multiplex Realtime Reverse Transcription PCR Assays for Simultaneous Detection of SARS-CoV-2, Influenza A/B, and Respiratory Syncytial Virus in Nasopharyngeal Swabs
10.3346/jkms.2021.36.e328
- Author:
Jiwon YUN
1
;
Jae Hyeon PARK
;
Namhee KIM
;
Eun Youn ROH
;
Sue SHIN
;
Jong Hyun YOON
;
Taek Soo KIM
;
Hyunwoong HYUNWOONG
Author Information
1. Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea
- Publication Type:Original Article
- From:Journal of Korean Medical Science
2021;36(48):e328-
- CountryRepublic of Korea
- Language:English
-
Abstract:
Background:In the coronavirus disease 2019 (COVID-19) pandemic era, the simultaneous detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza virus (Flu), and respiratory syncytial virus (RSV) is important in the rapid differential diagnosis in patients with respiratory symptoms. Three multiplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assays have been recently developed commercially in Korea: PowerChek™ SARS-CoV-2, Influenza A&B Multiplex Real-time PCR Kit (PowerChek; KogeneBiotech); STANDARD™ M Flu/SARS-CoV-2 Real-time Detection Kit (STANDARD M; SD BioSensor); and Allplex™ SARS-CoV-2/FluA/FluB/RSV Assay (Allplex; Seegene). We evaluated the analytical and clinical performances of these kits.
Methods:A limit of detection tests were performed and cross-reactivity analysis was executed using clinical respiratory samples. Ninety-seven SARS-CoV-2-positive, 201 SARS-CoV-2-negative, 71 influenza A-positive, 50 influenza B-positive, 78 RSV-positive, and 207 other respiratory virus-positive nasopharyngeal swabs were tested using the three assays. The AdvanSure™ respiratory viruses rRT-PCR assay (AdvanSure; LG Life Sciences) was used as a comparator assay for RSV.
Results:Except in influenza B, in SARS-CoV-2 and influenza A, there were no significant differences in detecting specific genes of the viruses among the three assays. All three kits did not cross-react with common respiratory viruses. All three kits had greater than 92% positive percent agreement and negative percent agreement and ≥ 0.95 kappa value in the detection of SARS-CoV-2 and flu A/B. Allplex detected RSV more sensitively than AdvanSure.
Conclusion:The overall performance of three multiplex rRT-PCR assays for the concurrent detection of SARS-CoV-2, influenza A/B, and RSV was comparable. These kits will promote prompt differential diagnosis of COVID-19, influenza, and RSV infection in the COVID-19 pandemic era.