3D printing assisted interventional therapy for congenital coarctation of aorta: 8 cases of analysis on clinical efficacy
10.3760/cma.j.cn112434-20200106-00006
- VernacularTitle:3D打印技术辅助介入治疗先天性主动脉缩窄8例
- Author:
Chennian XU
1
;
Zhenge FAN
;
Yang LIU
;
Hongliang ZHAO
;
Peng DING
;
Ping JIN
;
Lanlan LI
;
Yanyan MA
;
Jian YANG
Author Information
1. 空军军医大学西京医院心血管外科,西安 710032
- Keywords:
3D printing;
Coarctation of aorta;
Covered stent;
Interventional therapy
- From:
Chinese Journal of Thoracic and Cardiovascular Surgery
2021;37(7):399-403
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the feasibility and effectiveness of 3D printing aortic model for preoperative evaluation and surgical simulation, and to assist interventional treatment of coarctation of the aorta(CoA).Methods:From December 2017 to January 2019, 8 patients with congenital coarctation of the aorta who underwent percutaneous balloon dilatation and covered stent placement in Xijing Hospital of Air Force Military Medical University were analyzed retrospectively. Among them, 7 cases were male and 1 case was female. The age was(32.00±14.93) years old. Before operation, CT data of patients' heart and aorta were collected, reconstructed with Mimics software, and 3D printing technology was used to make the model of patients' aortic lesions. Before operation, the operation simulation was carried out to determine the best operation scheme and estimate the possible situation, and the relevant clinical data of patients during hospitalization and follow-up were collected.Results:One stent graft was successfully implanted into CoA through femoral artery in all 8 patients. The mean diameter of CoA increased from(3.70±2.94) mm before operation to(18.01±1.51) mm immediately after operation( P<0.05), and the mean systolic pressure difference decreased from(83.75±25.44) mmHg before operation to(14.63±8.09) mmHg after operation( P<0.05). The mean systolic blood pressure of the right upper extremity decreased from(204.13±22.31) mmHg before operation to(145.63±32.08) mmHg after operation( P<0.05), and there was no significant difference between the two groups. During the period of hospitalization and follow-up, no corresponding cardiovascular complications were found. Conclusion:The short-term effect of percutaneous balloon dilatation covered stent implantation on CoA in adolescents and adults is obvious. 3D printing model can reproduce the anatomical model of CoA site of patients individually, which is feasible and effective for the preoperative evaluation of CoA and the preparation of operation plan.