Predictive values of donor TIMP-2 and IGFBP7 in delayed graft function after kidney transplantation
10.3760/cma.j.cn421203-20210417-00131
- VernacularTitle:供者TIMP-2和IGFBP7对移植术后受者肾功能延迟的预测价值
- Author:
Chao ZHANG
1
;
Zhouji SHEN
;
Yimeng ZHU
;
Yina WANG
;
Xiaobo CUI
;
Xiaoren ZHANG
;
Pengjie XU
;
Xiaohui QIU
Author Information
1. 宁波大学附属李惠利医院肾内科 315040
- Keywords:
Kidney transplant;
Delayed graft function;
Tissue inhibitor of metalloproteinase
- From:
Chinese Journal of Organ Transplantation
2021;42(10):593-598
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the predictive values of tissue inhibitor of metalloproteinase-2 (TIMP-2) and insulin-like growth factor binding protein 7 (IGFBP7) in donor sera and lavage fluid on delayed graft function (DGF) in donation after circulatory death (DCD) kidney transplant recipients.Methods:A total of 33 eligible kidney donors and 33 corresponding recipients were recruited. Preoperative serum and renal perfusion fluid samples of donors were collected to determine the levels of TIMP-2 and IGFBP7. Patients were grouped according to whether DGF occurred after kidney transplantation and measured indicators analyzed. Independent sample t test was utilized for comparing the groups with normal distribution measurement data. And χ2 test was employed for comparing the groups with normal distribution counting data and Mann-Whitney test for comparing the groups with non-normal distribution measurement data. Receiver operating characteristic (ROC) curve and area under curve (AUC) were used for evaluating the diagnostic efficacy of indicators. Results:In donor-DGF group, lavage fluid TIMP-2, product of lavage fluid TIMP-2 and IGFBP7 (TIMP-2×IGFBP7), serum IGFBP7 and product of serum TIMP-2 and IGFBP7 (TIMP-2×IGFBP7) were higher than those in donor-non-DGF group ( P<0.05). The AUC of TIMP-2, TIMP-2×IGFBP7, serum IGFBP7 and serum TIMP-2×IGFBP7 in the diagnosis of DGF were 0.753 (95%CI 0.546~0.959), 0.747 (95%CI 0.510~0.984), 0.824 (95%CI 0.615~1.000) and 0.852 (95%CI 0.660~1.000) respectively. Conclusions:Donor serum IGFBP7, donor serum TIMP-2×IGFBP7, lavage fluid TIMP-2 and lavage fluid TIMP-2×IGFBP7 may be used for predicting the occurrence of early DGF after kidney transplantation. Among them, serum TIMP-2×IGFBP7 has the highest diagnostic efficiency and may be an excellent predictor of DGF occurrence.