Efficacy of general anesthesia for percutaneous pulmonary valve implantation
10.3760/cma.j.cn131073.20201212.00915
- VernacularTitle:全身麻醉用于经皮肺动脉瓣植入术的效果
- Author:
Hongdang XU
1
;
Hongqi LIN
;
Lin QIU
;
Liang ZHAO
;
Zhibin LANG
;
Jiaqiang ZHANG
;
Taibing FAN
;
Yu HAN
;
Zhaoyun CHENG
;
Chuanyu GAO
Author Information
1. 河南省人民医院 华中阜外医院 郑州大学华中阜外医院麻醉科 451464
- Keywords:
Anesthesia, general;
Pulmonary valve
- From:
Chinese Journal of Anesthesiology
2021;41(9):1105-1108
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To summarize the efficacy of general anesthesia for percutaneous pulmonary valve implantation (PPVI).Methods:The clinical data of 6 patients underwent PPVI under general anesthesia in Children′s Heart Center of Henan Provincial People′s Hospital from December 2017 to January 2020 were retrospectively analyzed.Systolic blood pressure, diastolic blood pressure, heart rate, central venous pressure, SpO 2 and regional cerebral oxygen saturation were recorded before anesthesia induction (T 1), after anesthesia induction (T 2), before beginning of surgery (T 3), before pulmonary valve implantation (T 4), during pulmonary valve implantation (T 5), immediately after pulmonary valve implantation (T 6) and when the patients left the operating room (T 7). Right ventricular systolic pressure, diastolic pressure, pulmonary artery systolic pressure and diastolic pressure were recorded at T 4 and T 6.The development of related complications during operation and the cardiac, liver and kidney functions before and after operation were recorded.The postoperative extubation time, intensive care unit stay time and hospital stay time were recorded. Results:Six patients (3 males, 3 females), aged (16±4) yr, weighing (41±12) kg, were analyzed.Compared with the value at T 1-4 and T 6, 7, systolic blood pressure, diastolic blood pressure, heart rate, regional cerebral oxygen saturation and SpO 2 were significantly decreased at T 5 ( P<0.05). Compared with the value at T 1-5, central venous pressure was significantly decreased at T 6, 7 ( P<0.05). Compared with the value at T 4, right ventricular diastolic pressure was significantly decreased, and pulmonary artery diastolic pressure was increased at T 6 ( P<0.05). No anesthesia- and surgery-related serious complications occurred among the patients.One patient was transferred to the ward after extubation in the operating room, and 5 patients were transferred to the intensive care unit after operation.All 6 patients were discharged successfully and entered the follow-up stage. Conclusion:General anesthesia provides better efficacy when used for PPVI, and hemodynamic monitoring of pulmonary circulation and systemic circulation should be strengthened during pulmonary valve implantation to maintain circulation stable.