99Tc m-DTPA SPECT/CT imaging in the diagnosis of cerebrospinal fluid leakage
10.3760/cma.j.cn321828-20200420-00157
- VernacularTitle:99Tc m-DTPA SPECT/CT显像对脑脊液漏的诊断价值
- Author:
Yunyun ZHU
1
;
Chentian SHEN
;
Zhenkui SUN
;
Hongjun SONG
;
Yang WANG
;
Ruisen ZHU
;
Weitian ZHANG
;
Quanyong LUO
Author Information
1. 上海交通大学附属第六人民医院核医学科 200233
- Keywords:
Cerebrospinal fluid otorrhea;
Cerebrospinal fluid rhinorrhea;
Tomography, emission-computed, single-photon;
Tomography, X-ray computed;
Technetium Tc 99m
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2021;41(10):617-621
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the diagnostic efficacy and clinical application value of 99Tc m-diethylene triamine pentaacetic acid (DTPA) SPECT/CT imaging in cerebrospinal fluid leakage (CSFL). Methods:A total of 23 patients (11 males, 12 females; age (44.2±15.1) years) who underwent endoscopic repair surgery for suspected CSFL in Shanghai Jiao Tong University Affiliated Sixth People′s Hospital between April 2018 and January 2020 were retrospectively reviewed. All patients performed 99Tc m-DTPA SPECT/CT imaging, paranasal sinus high resolution CT (HRCT) and MRI before surgery. The diagnostic efficacies of 3 imaging techniques were calculated according to the result of surgery regarded as the golden standard. χ2 test was used to compare the qualitative and localized diagnostic efficacies of 3 imaging techniques for CSFL. Results:Of 23 patients, 21 were finally confirmed with CSFL and 24 leak locations were identified according to the results of surgery; the other 2 patients had no obvious CSFL and no leak location was found during the operation. The sensitivity and accuracy of 99Tc m-DTPA SPECT/CT, MRI and HRCT for the diagnosis of CSFL were 100%(21/21) and 95.7%(22/23), 85.7%(18/21) and 82.6%(19/23), 76.2%(16/21) and 69.6%(16/23), respectively. The accuracy of 99Tc m-DTPA SPECT/CT, MRI and HRCT for the diagnosis of leak location was 79.2%(19/24), 50.0%(12/24) and 45.8%(11/24), respectively. There was no statistically significant difference of diagnostic efficacies for CSFL among 3 imaging techniques ( χ2 values: 0.451-3.453, all P>0.05). For leak location, the diagnostic efficacy of 99Tc m-DTPA SPECT/CT was significantly better than that of MRI and HRCT ( χ2 values: 4.463, 5.689, both P<0.05). Conclusion:99Tc m-DTPA SPECT/CT imaging shows an excellent diagnosis efficacy not only for CSFL but also for leak location, which is helpful for guiding surgery.