Assessment of Posterior Globe Flattening: Two-Dimensional versus Three-Dimensional T2-Weighted Imaging.
10.13104/imri.2015.19.3.178
- Author:
Jun Hyung ANN
1
;
Eung Yeop KIM
Author Information
1. Department of Radiology, Gachon University Gil Medical Center, Incheon, Korea. neuroradkim@gmail.com
- Publication Type:Original Article
- Keywords:
Posterior globe flattening;
Three-dimensional T2-weighted imaging (3D T2WI);
Increased intracranial pressure (IICP);
Optic nerve sheath diameter (ONSD)
- MeSH:
Brain;
Female;
Hemorrhage;
Humans;
Intracranial Pressure;
Meningitis, Bacterial;
Optic Nerve
- From:Investigative Magnetic Resonance Imaging
2015;19(3):178-185
- CountryRepublic of Korea
- Language:English
-
Abstract:
PURPOSE: To compare the frequency of posterior globe flattening between two-dimensional T2-weighted imaging (2D T2WI) and three-dimensional (3D T2WI). MATERIALS AND METHODS: Sixty-nine patients (31 female; mean age, 44.4 years) who had undergone both 5-mm axial T2WI and sagittal 3D 1-mm isovoxel T2WI of the whole brain for evaluation of various diseases (headache [n = 30], large hemorrhage [n = 19], large tumor or leptomeningeal tumor spread [n = 15], large infarct [n = 3], and bacterial meningitis [n = 2]) were used in this study. Two radiologists independently reviewed both sets of images at separate sessions. Axial T2WI and multi-planar imaging of 3D T2WI were visually assessed for the presence of globe flattening. The optic nerve sheath diameter (ONSD) was measured at a location 4 mm posterior to each globe on oblique coronal imaging reformatted from 3D T2WI. RESULTS: There were significantly more globes showing posterior flattening on 3D T2WI (105/138 [76.1%]) than on 2D T2WI (27/138 [19.6%], P = 0.001). Inter-observer agreement was excellent for both 2D T2WI and 3D T2WI (Cohen's kappa = 0.928 and 0.962, respectively). Intra-class correlation coefficient for the ONSD was almost perfect (Cohen's kappa = 0.839). The globes with posterior flattening had significantly larger ONSD than those without on both 2D and 3D T2WI (P < 0.001; 6.14 mm +/- 0.44 vs. 5.74 mm +/- 0.44 on 2D T2WI; 5.90 mm +/- 0.47 vs. 5.56 mm +/- 0.34 on 3D T2WI). Optic nerve protrusion was significantly more frequent on reformatted 1-mm 3D T2WI than on 5-mm 2D T2WI (8 out of 138 globes on 3D T2WI versus one on 2D T2WI; P = 0.018). CONCLUSION: Posterior globe flattening is more frequently observed on 3D T2WI than on 2D T2WI in patients suspected of having increased intracranial pressure. The globes with posterior flattening have significantly larger ONSD than those without.