Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography and Magnetic Resonance Imaging for Adverse Local Tissue Reactions near Metal Implants after Total Hip Arthroplasty: A Preliminary Report
- Author:
Makoto KIMURA
1
;
Nobuhiro KAKU
;
Yuta KUBOTA
;
Hiroaki TAGOMORI
;
Hiroshi TSUMURA
Author Information
- Publication Type:Original Article
- From:Clinics in Orthopedic Surgery 2021;13(3):320-328
- CountryRepublic of Korea
- Language:English
-
Abstract:
Background:Plain computed tomography (CT) and magnetic resonance imaging (MRI) are useful for diagnosing adverse local tissue reactions after metal-on-metal total hip arthroplasty (THA), but metal artifacts can hamper radiological assessments near the implants. We sought to clarify the usefulness of 18F-fluorodeoxyglucose positron-emission tomography (18F-FDG-PET) CT and MRI in the periprosthetic region, which is difficult to assess after THA due to metal artifacts.
Methods:We performed preoperative 18F-FDG-PET/CT and 18F-FDG-PET/MRI, as well as plain CT and MRI, in 11 metal-on-metal THA patients who underwent revision surgery.
Results:Most patients showed high FDG uptake in the metal artifact areas and pseudotumors in the 18-F-FDG-PET/CT and 18-FFDG-PET/MRI scans. Intraoperative intra-articular macroscopic and histopathological intra-articular granulation tissue findings were suggestive of adverse local tissue reaction.
Conclusions:The enhanced uptake in the metal artifact areas seemed to reflect adverse local tissue reaction. Therefore, 18F-FDGPET/CT and 18-F-FDG-PET/MRI can be useful for the auxiliary diagnosis of adverse local tissue reactions after metal-on-metal THA.