Correlation between Microalbuminuria Checked by RIA & Micral-Test®.
10.12701/yujm.1991.8.2.158
- Author:
Chan Woo LEE
;
Kyu Chang WON
;
Soo Bong CHOI
- Publication Type:Original Article
- Keywords:
Microalbuminuria;
RIA;
Micral-Test
- MeSH:
Methods;
Proteinuria;
Radioimmunoassay
- From:Yeungnam University Journal of Medicine
1991;8(2):158-163
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
It is evident that an elevation of airway albumin excreation rate without clinical proteinuria strongly predicts a later progression on diabetic renal disease. So we studied the correlation between Microalbumin checkly RIA & Micral-Test®. We collected urine between 08:00 h and 08:00 h next day and then checked microalbuminuria by radioimmunoassay method and Micral-Test® The results are as follows: 1. There was significant correlation between microalbuminuria checked by RIA & Micral-Test® 2. There was poor correlation between diabetes duration or HV-A1c and maximal change in albumin excreation rate. 3. So we concluded that Micral-Test® can be used in laboratory instead of RIA.