Reducing Dislocations of Antibiotic Hip Spacers via Hybrid Cement-screw Constrained Liner Fixation: A Case Series
- Author:
Richard A. PIZZO
1
;
Jay N. PATEL
;
Anthony VIOLA
;
David M. KELLER
;
Richard S. YOON
;
Frank A. LIPORACE
Author Information
- Publication Type:ORIGINAL ARTICLE
- From:Hip & Pelvis 2020;32(4):207-213
- CountryRepublic of Korea
- Language:English
-
Abstract:
Purpose:Infection following total hip arthroplasty is a challenging and devastating complication. In two-stage revision arthroplasty, antibiotic spacers, although efficacious, can be associated with an unacceptable rate of mechanical complications (e.g., fracture, dislocation). This series describes 15 patients with infected total hip prostheses treated with hybrid cement-screw fixation constrained liner antibiotic spacers to enhance stability and minimize mechanical complications.
Materials and Methods:All patients with an infected hip prosthesis undergoing two-stage revision arthroplasty at a single academic medical center were identified and screened for inclusion. Clinical and radiographic data including patient demographics and outcome measures were collected and retrospectively analyzed.
Results:Two patients died of unrelated causes at an average of 6-week postoperatively. Infections in the remaining thirteen patients (100%) were successfully eradicated; all underwent uncomplicated revision arthroplasty at a mean duration of 99.5 days after the placement of the antibiotic spacer. No dislocations, fractures, or other mechanical failures of any spacer were observed in this series.
Conclusion:The hybrid cement-screw fixation technique for constrained liner antibiotic spacers is a reliable and effective treatment method for eradicating prosthetic joint infections without mechanical complications.