Shielding calculation and discussion on high energy light source storage ring and synchrotron
10.3760/cma.j.issn.0254-5098.2021.02.012
- VernacularTitle:高能光源储存环及同步加速器屏蔽计算与探讨
- Author:
Zhen ZHANG
;
Xuetao WANG
;
Changsong HOU
;
Dexing LIAN
;
Weiguo ZHU
;
Fei CHEN
;
Yuwen LI
- From:
Chinese Journal of Radiological Medicine and Protection
2021;41(2):146-150
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source.Methods:The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding.Results:The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%.Conclusions:For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.