Diagnosis and prognosis of fetal isolated vascular ring by ultrasonography in the first trimester
10.3760/cma.j.cn131148-20200804-00624
- VernacularTitle:早孕期胎儿孤立性血管环的超声诊断及预后分析
- Author:
Shuihua YANG
;
Guican QIN
;
Guidan HE
;
Mengfeng LIANG
;
Zuojian YANG
;
Yulan PANG
;
Xinyan LI
;
Xiaoxian TIAN
;
Juansong TANG
;
Pingping LIU
;
Lu TANG
;
Sheng HE
- From:
Chinese Journal of Ultrasonography
2021;30(3):225-230
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the feasibility and prognosis of prenatal ultrasonic diagnosis of fetal isolated vascular ring at 11-13 + 6 weeks. Methods:A total of 36 996 fetuses were selected to compare the results of ultrasound screening at 11-13 + 6 weeks and 20-24 weeks of pregnancy in Guangxi Maternity & Child Healthcare Hospital from January 2016 to January 2020, the reasons for missed diagnosis and misdiagnosis of fetal isolated vascular ring by ultrasonography in the first trimester were summarized. Results:Thirty-five cases were diagnosed as isolated vascular ring in the first trimester, including 19 cases right aortic arch combined with aberrant left subclavian artery with "U-shaped" vascular ring, 7 cases double aortic arch with "O-shaped" vascular ring, and 9 cases aberrant right subclavian artery with "C-shaped" vascular ring. While 155 cases were diagnosed as isolated vascular ring at 20-24 weeks of pregnancy, consisting of 18 cases of combined with aberrant left subclavian artery, 9 cases of double aortic arch, 126 cases of aberrant right subclavian artery and 2 cases of pulmonary artery sling, the diagnosis coincidence rates were 94.74%, 77.78%, 7.14%, 0(Kappa value were 0.97, 0.88, 0.13, 0). For the diagnosis of right aortic arch combined with aberrant left subclavian artery, double aortic arch and aberrant right subclavian artery in the first trimester, the specificities were 99.99%, 100%, 100%, the sensitivities were 100%, 77.78%, 7.14%, the false-positive rates were 0.01%, 0, 0, the false-negative rates were 0, 22.22%, 92.86%, and the Youden′s indices were 0.99, 0.78, 0.07.Conclusions:Right aortic arch combined with aberrant left subclavian artery and double aortic arch have high coincidence rate by ultrasonography in the first trimester, while the diagnostic coincidence rate of isolated aberrant right subclavian artery was low. Ultrasound screening for isolated vascular ring in the first trimester still needs ultrasound examination in the second trimester to exclude the minor cardiac malformations that are difficult to diagnose in the first trimester.