Dynamic anterior plate-screw system for quadrilateral area in T-shaped acetabular fractures: a comparison of clinical efficacy between the first and the second generation
10.3760/cma.j.cn115530-20200701-00441
- VernacularTitle:第一代与第二代动力化前路方形区钛板螺钉内固定系统治疗髋臼T形骨折的疗效比较
- Author:
Qipeng SHAO
;
Xianhua CAI
;
Haiyang WU
;
Ranran SHANG
;
Chengjing SONG
;
Ximing LIU
;
Guodong WANG
- From:
Chinese Journal of Orthopaedic Trauma
2021;23(3):246-253
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the clinical efficacy between our first generation and second generation dynamic anterior plate-screw system for quadrilateral area (DAPSQ) in the treatment of T-shaped acetabular fractures.Methods:A retrospective study was conducted of the 28 patients with T-shaped acetabular fractures who had been treated at Department of Orthopaedics, General Hospital of Central Theater Command from January 2008 to December 2019. They were divided into 2 groups according to fixation methods. Group A [15 patients, 11 males and 4 females, an age of (43.5±9.1) years] were treated with the first generation DAPSQ while Group B [13 patients, 8 males and 5 females, an age of (42.5±7.0) years] with the second generation DAPSQ. Operation time, intraoperative bleeding, fracture reduction, function of the affected hip and postoperative complications were recorded and compared between the 2 groups.Results:The 2 groups were comparable because there was no significant difference between them in the preoperative general data ( P>0.05). The 28 patients were followed up for 12 to 60 months (average, 35.0 months). The operation time [(193.9±33.3) min] and intraoperative bleeding [(830.8±177.4) mL] for Group B were significantly less than those for Group A [(231.3±40.0) min and (1,043.3±190.7) mL] ( P<0.05). In Group A, according to the Matta scoring, the fracture reduction was rated as excellent in 8 cases, good in 5 and poor in 2; in Group B, the fracture reduction was rated as excellent in 8 cases, good in 4 and poor in one. According to the modified Merle d'Aubigné & Postel scoring at the final follow-up, the function of the affected hip was rated as excellent in 9 cases, as good in 3, as fair in 2 and as poor in one in Group A while as excellent in 9 cases, as good in 2 and as fair in 2 in Group B. There were no statistically significant differences between the 2 groups in reduction quality or in the function of the affected hip ( P>0.05). Follow-up observed hip traumatic arthritis in 2 cases in Group A and in one in Group B. Conclusion:In the treatment of T-shaped acetabular fractures, compared with the first generation DAPSQ, the second generation DAPSQ can shorten operation time and decrease intraoperative bleeding significantly, though both achieve comparable functional outcomes.