Evaluation of the effect of instant blood glucose monitoring system in perioperative blood glucose management in patients with hip fracture complicated with diabetes mellitus
10.3760/cma.j.cn211501-20201209-04779
- VernacularTitle:瞬感血糖监测系统在髋部骨折合并糖尿病患者围手术期应用的效果评价
- Author:
Minjie ZHANG
;
Aixiang WENG
;
Chen YANG
;
Xijuan WEI
;
Yanmei WANG
- From:
Chinese Journal of Practical Nursing
2021;37(13):967-972
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the effect of instant blood glucose monitoring system (FGM) in perioperative blood glucose management in patients with hip fracture complicated with diabetes mellitus, and to provide guidance for perioperative blood glucose management.Methods:A total of 100 patients with hip fracture complicated with diabetes mellitus treated in the Department of Orthopaedics, Gongli Hospital, Pudong New Area, Shanghai from July 2018 to July 2020 were selected as subjects.The patients were divided into experimental group and control group by random digits table method with 50 cases in each group. The patients in both groups adopted the mode of multidisciplinary cooperation.The experimental group was used to monitor blood glucose based on FGM, and traditional blood glucose monitoring was used in the control group. The waiting time before operation, the pain caused by blood glucose acupuncture, the satisfaction of patients and medical staff, the blood glucose level at different time points and the incidence of adverse reactions were compared between the two groups.Results:The waiting time before operation, the proportion of patients with moderate and severe pain after acupuncture and the incidence of hyperglycemia in the experimental group were (2.58 ± 1.30) d, 2% (1/50) and 30% (15/50), respectively, the control group were (3.67 ± 1.59) d, 22% (11/50) and 50% (25/50), respectively. The differences were statistically significant( t value was -2.087, χ2 values were 9.470, 4.170, P<0.05). The satisfaction of patients and medical staff in the experimental group were (46.43 ± 1.87), (46.58 ± 2.10) points, respectively, the control group were (40.67 ± 3.24), (43.84 ± 2.92) points, respectively.The differences were statistically significant( t values were 8.441, 8.087, P<0.05). There was no significant difference in fasting blood glucose, 2-hour postprandial blood glucose and pre-bedtime blood glucose between the two groups( P>0.05). Conclusions:The application of FGM can realize the continuous blood glucose monitoring and management of patients,making the blood glucose reach the standard more quickly and smoothly, meanwhile it may effectively shorten the waiting time before operation and reduce the acupuncture pain of blood glucose monitoring and recognize patients with concealed abnormal blood glucose. The application can improve the satisfaction of patients and medical staff, and promote the rapid recovery of patients as well.