Determination of three components in Shenqi-Yiqi oral liquid with HPLC combined with switching wavelengthmethod
10.3760/cma.j.cn115398-20200512-00087
- VernacularTitle:高效液相色谱波长切换法同时测定参芪益气口服液中3种成分含量
- Author:
Ping LI
;
Jin ZENG
;
Renhao OU
- From:
International Journal of Traditional Chinese Medicine
2021;43(3):268-271
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To establish the high performance liquid chromatography (HPLC) combined with switching wavelength method to determinate chlorogenic acid, ferulic acid, Calycosin-7-glucoside in Shenqi-Yiqi oral liquid. Methods:The Shenqi-Yiqi oral liquid was separated on an Agilent HC-C18 column by gradient elution using acetonitrile (A) - 0.1% phosphate (B) as the mobile phase. The flow rate was 1.0 ml/min. The detection wavelengths were 260 nm (chlorogenic acid and Calycosin-7-glucoside), 316 nm (ferulic acid) by wavelength conversion method. Results:The linear ranges of chlorogenic acid, ferulic acid, Calycosin-7-glucoside were 70.40-704.00 μg ( r=0.999 8), 1.36-13.60 μg ( r=0.999 8), 1.28-12.80 μg ( r=0.999 7), the average recovery rate were 99.44% ( RSD=2.54%), 101.06% ( RSD=1.57%), and 98.00% ( RSD=2.09%). Conclusion:This method is convient, rapid and accurate for determinating chlorogenic acid, ferulic acid and Calycosin-7-glucoside in Shenqi-Yiqi oral liquid.