Characteristic changes of finger skin temperature in cold provocation test in workers with vibration white finger
10.11763/j.issn.2095-2619.2017.06.011
- Author:
Bin XIAO
1
;
Qingsong CHEN
;
Qianling ZHENG
;
Guiping CHEN
;
Danying ZHANG
;
Hansheng LIN
;
Hanlin HUANG
Author Information
1. School of Public Health,Shanxi Medical University Taiyuan,Shanxi 030001,China
- Publication Type:Journal Article
- Keywords:
Cold provocation test;
Hand arm vibration;
Vibration white finger;
Skin temperature;
Rewarming
- From:
China Occupational Medicine
2017;44(06):716-724
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To analyze the changes of finger skin temperature in cold provocation test( CPT) in workers with vibration white finger( VWF). METHODS: A total of 245 male workers engaged in hand arm vibration operation was selected as study subjects using random number table method. All subjects were divided into VWF group( 73 persons) and control group( 172 persons). CPT( 10 ℃,10 min) was performed and the skin temperature of 6 fingers( index finger,middle finger and ring finger of both hands) was measured at pre-CPT adaptation period( 0,10,20,30 min) and after CPT period( 0,5,10,15,20,25,30 min). RESULTS: The effect of interaction between grouping and observe time was statistically significant on finger skin temperature( P < 0. 01). In the pre-CPT adaptation period,there was no statistically significant difference on skin temperature between 10 and 30 min time point in the two groups( P > 0. 05). After CPT,the fingers skin temperature of VWF group was lower than that of control group at 5 min time point( P < 0. 05),but there were no statistically significant differences on fingers skin temperature of other time points between the two groups( P > 0. 05).In both groups,the finger skin temperature at 0 min time point after CPT were lower than other time points in the same group( P < 0. 05),and the finger skin temperature increased with time( P < 0. 01). However,the finger skin temperature at 30 min after CPT did not restore to that at 30 min time point of pre-CPT. Except the VWF group,the abnormal rewarming temperature at 5 min time point after CPT of left index finger,the right index finger and the right ring finger were higher than that of the control group( 72. 6% vs 56. 4%,75. 3% vs 57. 6%,86. 3% vs 65. 1%,P < 0. 05),but there were no statistically significant differences on the abnormal rewarming temperature at 10,30 min time points of the six fingers in the two groups( P > 0. 05). There were no statistically significant differences on the detection rate of abnormal rewarming temperature between left index finger and the right index finger,or the right index finger and the right ring finger in the VWF group( 72. 6% vs 75. 3%,75. 3% vs 86. 3%,P > 0. 05). CONCLUSION: When CPT( 10 ℃,10 min) was performed in workers engaged in hand arm vibration operation,it is recommended to measure the finger skin temperature of index finger,and adaptation time before CPT can be adjusted to 10 min.